NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/Asbestos - BOX 17/105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER
Document / 42 pages

Fax cover sheet, 105 Duane Street site file

Machine-extracted title · confidence 90%

Cover sheet for a fax transmission from DEP regarding the 105 Duane Street site file.

NYC-WTC_000125801–000125842

Folder label: “105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER”

Page image
Scanned page image, NYC-WTC_000125806
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

(Page 6 of 7)

1 DEC-12-2001 17:48 NYC D.E.P. PUBLPC AFFAIRS

ACTS ACTS, CRAMTS AND TBAT%.A SABZTY iii Thopsoa ■t., 0 23 Now York, NY 100i2-2086 23,2/177-QOca n-x►eLl 1ACTi$YCR68. a0a hefts //«wr.sasewi.aw/aaa Joel R. Xupf.riosn, Req. Executive Director New York E}svironmental Law a Just3C! Project 315 Broadway - Suite 200 plow York NY 1000?-.121 December 11, 2001

Dear Joel K pfermsn,

I have reviewed the December 9, 2001 report an asbestos sampling done by Ed Olmsted, cIv, at 105 Duane street. i concur with Mr. Olmsted'a conclusion tbAt the eamle taken from the air diffuser in the loth floor public hallway .$.ewe levels of asbestos well above the recommended limit of 2.000 structure per square centimeter. I also concur that the finding of 555,000 asbestos structure per square eeatim.ter is a clear %ndication that the ventilation system should be cleaned by a professional duct cleaning compafY using vacuum and cleaning equipment designed fog asbestos dseontu tnation. z would add that the work moat be done by trained and certified asbestos abatement workers who can prevent contamination of other parts of the building while they work. 2 also would add that this single sampLe should be followed up by other samples taken from other locations in the ventilation system.. This sampling must be undertaken immediately because asbestos fibers in ventilation systems are likely to deposit throughout the building. The reading of 740 asbestos structures is high enough per square centimeter on the living room table tophazardous. to cause concern that further deposition could be It levels the elsani~i is delayed until many spartmenti attain pcneritially. requiring abatement, the cost of cleanup will rice a It is also 113e1 that there are already apartments in the building in which the asbestos duct levels are much higgher. These locations are most likely to be those in which the air is supplied by diffusers that are closer to the ventilation system's air intakes and filters. people living in these apartments may be at risk now. R ctfully ;;~ c r-; tsoaona Rossol, 14.S., M.P.k. , industrial hygienist

1212 637 3561 P.06 DEC-12-2001 17:22. LWNYC0308311

NYC-WTC 000125806

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125806Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →