NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 31/Buildings 105 Duane 80 John Gateway etc. 75 Park 200 Rector Trinity Church
Document / 7 pages

DEP Bureau of Public Affairs Fax Transmission Form, Dec 12,

Machine-extracted title · confidence 95%

Blank or partially filled fax cover sheet from the DEP Bureau of Public Affairs regarding environmental protection matters.

NYC-WTC_000154645–000154651

Folder label: “Buildings 105 Duane 80 John Gateway etc. 75 Park 200 Rector Trinity Church

Page image
Scanned page image, NYC-WTC_000154650
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document DEC-12-2001 17:48 NYC D.E.P. PUBLFC AFFAIRS P.06/07

ACTS ABTS, CRAFTS AND THEAOB SAFETY 181 'JhOBSPBOn st., # 33 New York, NY 10013*2886 ai2/7'J'J.flasa E-hiail ;aCT89yc«t«. e«n hits I //w«w .eattwtb. c^AGia Joel R. Kupfecman, Bag. Executive Director New York Etivironmeatal Law & Justice Project 31S Broadway . Suite 200 New York NY 10007-1121 December 11> 2C01 Dear Joel Kupferman, I have reviewed the Decewber 9, 2001 report on asbestos a amp ii ng done by Ed Qlmated, CIH, at IOS Duane Street. I concur with Mx. Olmsted's conclusion that the sample taken from the air diffuser in the 10th floor public hallway shows levels of aabeBtos well above the recommended limit of lOOO structure per square centimeter. I also concur that the finding of 555,000 asbestoe structure per square oentimeter is a clear indication that the ventilation system should be cleaned by a professional duct cleaning company using vacuum and cleaning equipment designed for asbestos decone&mlnation. i would add that the work must be done by trained and certified eebeetos abatement workers who can prevent contamination of ether parts of the building while they work. I also would add that this single sample should be followed up by other eamples taken from other locations in the ventilation system. This saw^ling must be undaxtakaa immediately because aabestofl fibers in ventilation eyetens are likely to deposit throughout the building. The reading of 740 asbeetos structures per sguare eantimeter on the living room table cop is high enough to cause concern that further deposition could ba hazardous. If the cleaning is delayed until many apartment® attain levels requiring abatement, the cost; of cleanup will rise exponentially. It ia also likely that there are already apartments In the building in which th© aabeetos duet levels are much higher- These locations are most likely to be chose in which the air is supplied by diffusers that are cloear to the ventilation eyetarn's air intakes and filters. People living la these apartmente may be at risk now. Respectfully ew ed.

Konona ROB3O1, M.S., M.f.A., industrial bygieniat

DEC-12-2001 17:21 1212 637 3561 P.06 NYC-WTC_000154650

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000154650Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →