NYC 9/11 Public Portal Document
Mr. Shaun Hession
New York City Housing Authority
November 12, 2001
•
EMTEQUE Page 7
ensure that the mercury could be completely removed. On Saturday November
3, 2001, EMTEQUE conducted sampling of a single piece of paper that had been
covered with heavy levels of dust since September 11, 2001. A second piece of
paper was obtained from an area considered to have a medium level of dust. A
third piece of paper was obtained from within a file cabinet that had some dust
infiltration. A fourth piece of paper was obtained from an unopened ream of
paper to serve as a control sample. Belfour conducted all cleaning of the paper
products.
Due to the levels of dioxins, PCBs, PAHs and mercury observed (with the
realization that none of these contaminants would typically be expected to be
found in an office environment — or most other environments), EMTEQUE
recommends that porous materials (i.e., carpeting, cubicle dividers, ceiling tiles,
etc.) be disposed. EMTEQUE's recommendation is based on the fact that it may
be difficult (or perhaps impossible) to clean these items. Though EMTEQUE
anticipates that cleaning may provide a small cost savings over replacement, the
issues of attempting to clean these materials, ensuring their cleanliness at the
completion, and ensuring employees' satisfaction with those materials will at
least be very difficult. If an attempt is made to perform cleaning of porouse
materials, EMTEQUE recommends that a pilot study be performed to ensure that
any cleaning performed will be sufficient and successful prior to starting a
complete cleaning program.
Recommendations for access, clean-up procedures, salvage of equipment,
personal protective equipment, engineering controls, training, etc. will be
•
identified in future specifications and procedures to be drafted by EMTEQUE and
approved by NYCHA.
dioxins,
Due to the concentrations detected in the sampling for PCBs, PAHs and
EMTEQUE recommended additional sampling. This work was approved by
NYCHA and conducted by EMTEQUE on Thursday and Friday, October 25 and
though
26, 2001. This data was not received in time to incorporate into this report
much of this data has already been incorporated Into the summary tables
incorporated
included as an attachment to this report. This additional data will be
into the text of the final site assessment report. The additional sampling was
anticipated to allow EMTEQUE to characterize the dust and debris throughout
elevated
the entire space. The additional sampling results for dioxin indicate that
dioxin levels are present in various areas throughout the various floors.
at
Should you have any questions or require additional information, please contact us
(212) 631-9000.
Submit ed bey, Re edby,
lj
ell A. Feldscher, Eric Telemaque
Senior Environmental Manager President
Attachments
NYC-WTC 000124620
OCR can misread numbers and units. Confirm readings against the page image before using them.