Asbestos air sample TEM analysis report for 99 Church Street,

Machine-extracted title · confidence 95%

Laboratory report from ATC Associates providing transmission electron microscopy results for air samples collected at 99 Church Street.

NYC-WTC_000124304–000124612

Folder label: “99 CHURCH STREET Block: 123 Lot: 10 BIN: 1001396 26/42 PARK PL, 23-41 BARCLAY ST

Page image
Scanned page image, NYC-WTC_000124312
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/12/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: 99 Church Street, 99 Church St., NY, NY TEM Sample No.: 5670 - 60956 Lobby Date Received: 10/12/01 Grid Openings Analyzed: 4

Project Sample No.: L-6 Average Grid Opening: 106.00 um

Air Volume: 1800 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0.0048 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct. >-5um Struct/mm2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected ---------------------------------------------------------------------------------------------------------------------------------- The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

NYC-WTC 000124312

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000124312Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →