( M%TC ASSOCIATES INC. Project Memorandum

Subject: 225 Rector Place Re: Ambient Air Sampling To: Peter Hoyle Related Management From: Fred Burkhardt Date: December 3, 2001

On November 28, 2001, ATC collected one ambient air sample in each of the apartments listed below, and one sample In five common hallways of the building, to ascertain the presence or absence of airborne asbestos. All samples were collected and analyzed In accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763, Subpart E, Appendix A. Apartments sampled are identified in the following table.

I. S. ii1ji,iiiii Penthouse 11 P11 23 P11 10 PII Hallway _._._._._._._. 22 9 21 PII _._; 8 20 ;P11 Hallway 7 ;P II _._._._ 19 --.-.-Pll 6 18 5 Pll; Haliwa 17 _ 4 ~ II 16 PII 3 15 Hallway 2 14 1 Piltobby 12 P11 Basement

In the absence of a specific ambient air standard, ATC has selected as a criteria for acceptable ambient air sample sets, the AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm2) per sample set. This criteria has been selected because the AHERA requirement Is the most stringent reocc upanay requirement available, and has been designed to be protective of children following an asbestos project. Based upon analytical sample results for all samples recording levels below the AHERA clearance requirement, it Is ATC's opinion that the ambient air samples collected throughout the building are representative of the ambient conditions at the time of testing and that the areas tested meet an acceptable criterion for re-occupancy. If you have any questions or require additional explaination of the information presented please do not hesitate to call me at 212-353-8280.

Thank You.

NYC-WTC 000123910

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000123910Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000104321 · Box DEP Box 36

Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.

Cited alongside this record in an Ask answer

NYC-WTC_000161636 · Box DEP Box 42

Agenda listing panelists from federal agencies, unions, and city departments for a March 2004 conference on post-9/11 air quality.

Cited alongside this record in an Ask answer

Compare copies and versions →