Project Memorandum ASSOCIATES INC.

Subject: 225 Rector Place Re: Ambient Air Sampling To: Peter Hoyle Related Management From: Fred Burkhardt Date: November 19, 2001

apartments listed below, one On October 31, 2001, ATC collected one ambient air sample In each of the sample In five common areas (hallways) of the building and five outdoor samples, to ascertain the presence or absence of airborne asbestos. All samples were collected and analyzed in accordance with Electron Microscopy (TEM) method as set forth at 40 CFR Part 763, Subpart E, the AHERA Transmission Appendix A. Apartments sampled are identified in the following table.

.. .. . Penthouse - --- - ----------------------- - 11 - --------------------- -....... - 23 10 22 9 21 8 20 7 19 6 18 5 17 4 16 3 15 2 14 1 --- -------------------------- - 12

as a criteria for acceptable ambient In the absence of a specific ambient air standard, ATC has selected asbestos abatementaction of an air sample sets, the AHERA re-occupancy requirement following an per sample set. This average of less than 70 asbestos structures per square millimeter (<70 s/mm2) reoccupancy AHERA requirement Is the most stringent criteria has been selected because the asbestos project. requirement available, and has been designed to be protective of children following an

below the AHERA clearance Based upon analytical sample results for all samples recording levels requirement, it Is ATC's opinion that the ambient air samples collected throughout the building are representative of the ambient conditions at the time of testing and that the areas tested meet an you have any questions or require additional explaination of the acceptable criterion for re-occupancy. If information presented please do not hesitate to call me at 212-353-8280.

Thank You.

NYC-WTC 000124174

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000124174Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000104321 · Box DEP Box 36

Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.

Cited alongside this record in an Ask answer

NYC-WTC_000161636 · Box DEP Box 42

Agenda listing panelists from federal agencies, unions, and city departments for a March 2004 conference on post-9/11 air quality.

Cited alongside this record in an Ask answer

Compare copies and versions →