NYC 9/11 Public Portal Document
NOV. 15. 1 l1 5:46PM JLC ENVIRONMENTAL NO.752 P.14/14
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2200
Milford Management Corp. ELAP Lab Code: 11029
Analyte: ASBESTOS
20 West 64th Street NIOSI-1 and AIHA Lab Code: 100273
Date Received: 11/15/01
New York, NY 10023 NVLAP Lab Code: 101953 Date Analyzed: 11/15/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch M. 01110430
Site: I 99 Battery Place, New York, NY
Iii
SAMPLE #
DATE ASBESTOS TOTAL % OF
OESCRlPTlON/LOCATlQN COLOR CONS77TUENTS
COLLECTED DETECTED? ASBESTOS
LAB#
CUENT'S SAMPLE
034 Roof/ Water Tower Roof/ North Side! BLACK NO 0% CELL 5%
11/14101 Sample of Roof Debris Dark FBGL 5%
12845 NFIB 90%
034F
035 Roof/ High Roof/ East Side/ Sample of BLACK NO 0% CELL 25%
11/14/01 Roof Debris Dark FBGL 30%
12848 NFIB 45%
035F
036 Roof/ High Roof/ West Side! Sample of BLACK NO 0% CELL 20°/-
11/14101 Roof Debris Dark FBGL 30%
12847 NFIB 50%
036F
INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED NOT ANALYZED POsmVP STOP
Ssmde-Analvs~s by: ASBESTOS CONS111i NTs NOW-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dlsperslon Staining (PLM-OS) CHRY = Cflrysotile Asbestos PAPF 4 Paper Fiber
AMOS = Amoshe Asbestos MINW = Mineral Wool
Method of Samc &_Preparation And Anelvela, CROC = Crocidotlte Asbestos FBGL = Fiberglass
ACTN = Ac*tollte Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed In gccof4 nce with the EPA TREM c Tremodte Asbestos CELL = Cellulose
'Method for the Determlrleilon of Asbestos In Bulk Building Materials' ANTH O Attthophyllte Aabestoa NFIB = Non-Fibrous
USEPA/ 600/ R-93(116, Jtlfy 1993. ORGY = Organic Matalal
WOU.. = Wollastonite
Irysmtmentatlon- HSHR = Horse Hair
OTHR = Other
Olynlpus PUM. Model BH-2NM Stereomlcroscope, Model
VMZ lx-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make tip of the materials only In the areas sampled. This 'Summary of Ar,aMlcal Results' shjll not be reproduced except In full, wlgrout the written
approval of JLC Laboratory, and It must not be used by client to clalm product endorsement by NVLAP or any agency of the U.S. Government. This method is riot applicable to
samples containing large amounts of fine fibers below the resolution of the light mkroscops. The value of this method is limier to the quantitative Identification of asbestos
and the eernl-quandtallve determination of asbestos content of bulk apn{ples, expressed ass percentage of the protected area. Quantftatlon of asbestos content was
determined with a visual volume estimate, a calibrated Visual area eadNte, apolor point counting procedure. CAUTION: Other fibers with optical propeq ea similar to asbestos
may give positive IMarterencea and will be considered asbestos under this methodology. Also, PLM is not consistently reliable In detecting gsbestas In floor coverings and
similar non-friable orraanlceiiy-band materials. Quantitative transmission electron microscopy Is currently the only method that am be used to determine If this material can be
considered or treated as nort-aebeetoa containing.
Page 2 of 2