NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2089
Rose Associates ELAP Lab Code: 11029
Analyte: ASBESTOS
200 Madison Avenue NIOSH and AIHA Lab Code: 100273 Date Received: 9/19/01
New York, NY 10016-3901 NVLAP Lab Code: 101953
Date Analyzed: 9/19/01
Batch#: 0109B370
SUMMARY OF ANALYTICAL RESULTS - PLM
Site:
T 21 West Street, New York, NY I
SAMPLE #
ASBESTOS TOTAL % OF CONSTITUENTS
DATE
COLLECTED DESCRIPTION/LOCATION COLOR DETECTED? ASBESTOS
LAB #
CLIENTS SAMPLE #
001 Apartment 91/ Window Sill/ Sample of TAN NO 0% CELL 20%
9/18/01 Dust FBGL 65%
10468 NFIB 15%
001A
002 Apartment 22K/ TV Stand/ Sample of Dust TAN NO 0% CELL 20%
9/18/01 FBGL 65%
10469 NFIB 15%
002B
003 Apartment 3E/ Desk/ Sample of Dust TAN NO 0% CELL 15%
9/18/01 FBGL 70%
10470 NFIB 15%
003C
*INSUFFICIENT MATERIAL SUBMITTED ^"TEM RECOMMENDED NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC - Crocidolite Asbestos FBGL = Fiberglass
Method of SamA ple Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed In accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos In Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-931116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2A/M Stereomicroscope, Model
VMZ 1x-4x. Al Wallner
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method Is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative Identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitatlon of asbestos content was
determined with a visual volume estimate,.a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive Interferences and will be considered asbestos under this methodology. Also, PLM Is not consistently reliable In detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine If this material can b
considered or treated as non-asbestos containing.