Environmental sampling summary, 280 Rector Place, Oct 2001

Machine-extracted title · confidence 95%

Summary of visual assessments and environmental testing for asbestos at 280 Rector Place conducted shortly after September 11.

NYC-WTC_000120550–000120602

Folder label: “280 RECTOR PLACE Block: 16 Lot: 7506 BIN: 1065199 295 West Thames Street, The Soundings

Page image
Scanned page image, NYC-WTC_000120551
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

en,ulr0n men taI

services, inc.

February 12, 2002

Mr. Thomas Swietek c/o Brown Harris Stevens Residential Mgt. 770 Lexington Avenue New York, New York 10021

Re: Ambient Air Quality Testing Results The Regatta Condominiums 21 South End Avenue, New York, NY

Dear Mr. Swietek,

ACS Environmental Services, Inc. was retained to conduct ambient air quality testing at the above referenced project site. The testing was performed between the dates of October 5, 2001 and November 19, 2001. Air quality samples were collected in selected random locations.

The samples collected were conducted within strict accordance with all federal, state and local laws governing asbestos. All samples were submitted under a Chain of Custody Form to Scientific Laboratories, Inc., a NYS Certified Testing Lab, ELAP ID No.11480. The method of sample analysis performed was Transmission Electron Microscopy (TEM analysis). The samples were prepared and analyzed according to the AHERA Protocol (Asbestos Hazardous Emergency Response Act) as contained in 40 CFR, Part 763, Subpart E, Appendix A.

Analytical results of asbestos air samples analyzed by TEM Analysis are measured in structures per square millimeter (struc/sq.mm). The Clean Air Standard as set by the US Environmental Protection Agency (EPA) is 70 struc/sq.mm. After analysis of the air samples collected it was determined that the air quality in the areas sampled, at the time of testing indicated on the air sampling data forms were less than 70 struc/sq.mm.

The table on the following page summarizes the samples collected, indicating the dates of samples collected, the location of each sample and the laboratory analytical results.

ACS ENVIRONMENTAL Page 1 SERVICES, INC. 2i;; 1 - -.r ecresr .Avenue

:Kiyn, Y. , 1229 ;78 339-1984 FAX: (718) 998-6373 NYC-WTC 000120551

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000120551Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →