NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 47/60 BROAD STREET 1000817, 24/1
Document / 9 pages

Scope of work exhibit, 60 Broad Street, 2002

Machine-extracted title · confidence 90%

Exhibit defining regulatory compliance requirements for environmental cleanup work at the site.

NYC-WTC_000118416–000118424

Folder label: “60 BROAD STREET 1000817, 24/1

Page image
Scanned page image, NYC-WTC_000118416
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document enf .ie/ 2ab2 i.6: 23 2124838895 CRG PAGE 10

4

Exhibit A New York City Department of Environmental Protection Bureau of Environmental Compliance

Asbestos Control Program

Building Exterior Clean-up ScopeofW r _ork All work performed shall be in compliance with all applicable, relevant, and appropriate regulations, including but not limited to those of the United States Environmental Protection Agency (USEPA), the United States Department of Labor Occupational Safety and Health Administration (OSHA), the New York State Department of Labor (NYS DOL), the New York State Department of Environmental Conservation (NYS DEC), the New York State Historic Preservation Office (SHPO), the New York City Department of Sanitation (DOS), the New York City Department of Health (DOH), the New York City Landmarks Preservation Commission (NYC LPC), and the New York City Department of Environmental Protection (DEP)_

Bac keround The DEP with assistance from representatives of the NYS DOL and US EPA performed follow-up site visits at buildings in the vicinity of the World Trade Center. The visual assessments disclosed the presence of various amounts of debris with various dispersal patterns at the building exteriors. Tie majority of buildings had isolated areas of debris specifically at the perimeter of the roofs, at the base of parapet walls, and in gutters. Debris was also visible at horizontal surfaces on some of the building facades. For some buildings, building facades facing the street were cleaned while the facades at the rear remained dirty.

The observed debris was characteristic of the debris from the impact of September 11, 2001. The debris appears to have reformed into a dense mass (caked). During the DEP follow-up visits, samples of the debris were collected from various roofs. The uneven dispersal identified above was also evident in the sample collection. Samples collected from various buildings indicated that some of the debris was asbestos-containing material (ACM). Based on these results and the most stringent assessment and evaluation, this material maybe ACM and shall be cleaned by and NYSDOL certified workers. NYS DOL licensed contractors with DEP

Purpose A NYS DOL licensed asbestos contractor with DEP and NYSDOL certified workers shall perform the clean-up of building roofs, setbacks, and/or building facades within of work for the clean-up activities is attached. The the vicinity of the WTC. The scope clean-up activities shall consist of collection of debris and wet eleaning/HEpA vacuuming until the surfaces are clean of visible debris. Contract Term and Specifications The contract shall be in force for 120 consecutive calendar days from the DEP commear.,,.anent date. Services shall be directed by the DEP. Contractors shall be prepared to mobilize within 72 hours of the contract award. The DEP expects contractors to provide four to handlers per day at each of the areas. Multiple building roofs shall five crews with a minimum of five be cleaned simultaneously. Work shall not be performed at any building found to be structurally unsound. Page 1 05/03/02

NYC-WTC 000118416

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000118416Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →