HVAC inspection report, 2 South End Ave, Jan 2003

Machine-extracted title · confidence 92%

Letter from Athenica Environmental Services reporting HVAC and environmental inspections performed on January 15, 2003.

NYC-WTC_000117831–000117892

Folder label: “2 SOUTH END av 1082813, 16/7511”

Page image
Scanned page image, NYC-WTC_000117891
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 2.1 Central Venlilation System Visual Inspection Form Venrilation System Identification: LOBBY Location: GROUND FLOOR GIMAFEA 2SOUTHEND ATE Associated mechanical room: clean VY_ _N dryXY System Components [NOTE: if component n t present (NP), net found (NI) or inaccessible (D) please indicate in last column] Outside air intake: Location: Area ServeLogEy stored chemicals/refuse Surface Dust/ Debris Present? Y/N WTC Dust Present? Accessible for inspection? Y_ _(explain): -louvers, grates and/or screens - outside air duct - outside air damper(s) Air handling unit: - outside air mixing chauber - filter rack(s) - filter media - blower assembly incl. Hlower wheel, blower housing, air vanes, in-line noise attenuators - blower housing acoust sal lining - pre-heat coils - heating coils - cooling coils - Ie-heat coils - condensate drain pan - supply air plenum - supply air plenum damper(s) - vibration collars Supply air distribution: - Supply air ducts Est. to al ln ft 400 Specify type (circle): mete! fibrous giass lined metal No. locations inspected 03 masonry fbrous glass board flex-luct wood - Accessible in-line fire dam.pers Est. total qty - Accessible turning vanes Est. total qty -In-line reheat/cooling coils Est. total qty - Supply air diffusers Est. total qty |) No. locations inspected No. locations inspected No. locations inspected No. locations inspected 3 Return air distribution: - Return air ducts Est. total In ft 2 Specify type (circle): (metal) fibrous &lass lined metal No. locations inspected masonry fibrous glass board flex-c uct wood - Return air plenum Est total RA plenum areas_1 - Return air plenum damper Est. total qty - Accessible in-line fire darupers Est. total gty. - Accessible turning vanes Est. total qty - Return air grilles Est. total qty No. locations inspected_ No. locations inspected No. locations inspected No. locations inspected _ No. locations inspected 1 Y Y Y Y Y N N N N N N N N Y Y Page 1 of 2 Component • not present • not found • inaccessible NP NP NP NP NP NP NP NP NP NP NP NF NP NP NP NP NYC-WTC_000117891

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117891Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117893 · Box DEP Box 46

Duplicate or continuation of the Athenica Environmental Services letter regarding HVAC inspections at 2 South End Avenue.

Similar indexed content

Compare copies and versions →