HVAC inspection report, 2 South End Ave, Jan 2003

Machine-extracted title · confidence 92%

Duplicate or continuation of the Athenica Environmental Services letter regarding HVAC inspections at 2 South End Avenue.

NYC-WTC_000117893–000117954

Folder label: “2 SOUTH END av 1082813, 16/7511

Page image
Scanned page image, NYC-WTC_000117947
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 201 Central Venlilation System Visual Inspection Form Ventilation System Identification: A LC ELEVATOR ROOM Location: UPPER BULKHEAD Associated mechanical rom: clean_ dry XY N Area Served: ELEVATOR RoOM stored chemicals/refuse YXN System Components [NOTE: if component act preseut (NP), net found (NF) or inaccessible (*) please indicate in last column] Outside air intake: Location: Accessible for inspection? Y (explaia): - louvers, grates and/or screens - outside air duct - outside air damper(s) Air handling wnit: - outside air mixing chaaber - filter rack(s) - filter meaia - blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attennators - blower housing acoust cal lining - pre-heat coils - heating coils - cooling coils - re-heat coils - condensate drain pan -sapply air plemam -supply air plenum damper(s) - vibration collars Supply air distribution: - Supply air ducts Est. toral In ft 4 Specify type (circle): met! fibrous glass lined metap No. locations inspected__ 2 masonry fibrous glass board fexluct wood - Accessible in-line fire dam pers Est. total gty - Accessible turning vanes Est. total oty - II-line reheat/cooling coils Est. total qty - Supply air diffusers Est total qty Return air distribution: No. locations inspected No. locations inspected No. locations inspected No. locations inspected_ 2 - Return air ducts Est. total In ft 4 Specify type (circle): meta Ebrous glass lined metal No. locations inspected_ masonry fibrons glass board flex-cict wood - Return air plenua Est. total RA plenum areas - Retura air plenum damper Est. total qty - Accessible in-line fire darapers Est. total qty - Accessible turning vanes Est. total gty - Return air grilles Est. total qty No. locations inspectedL No. locations inspected .No. locations inspected No. locations inspected _ No. locations inspectedL Surface Dust/ Debris Present? WTC Dust Present? Y Y Y Y N N N N N N N N Page 1 of 2 Component • not present • not found • tnaccessible NP NP NP NP NP NP NP NP NP NP NP NYC-WTC_000117947

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117947Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117830 · Box DEP Box 46

Detailed list of mechanical components including fans, ducts, dampers, and grilles located at the South End Avenue facility.

Filed in the same folder

NYC-WTC_000117831 · Box DEP Box 46

Letter from Athenica Environmental Services reporting HVAC and environmental inspections performed on January 15, 2003.

Filed in the same folder

Compare copies and versions →