NYC-WTC_000121258
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
13 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗Cover page for a fax transmission dated September 28, 2001, containing confidential environmental data.
NYC-WTC_000117772–000117793Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083378 365 South End Avenue, Building #300”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
D.C. Robert Avaltroni TEL:718-595-4544 Oct 15 01 6:48 No.001 P.03 •' Page 2 of2
"The importance of HP Environmental's results Is the discovery of themicroscopic size of the particles. The EPA's tests are now Irrelevant." "The building owners are responsible for this." "The trucks of debris being carted to the barge at Pier 26 should bewetted down and covered and we can ail see that is not always happening." "Lead contamination is definitely a concern, There is no safe level."
Joel Kupferman, Attorney with the NY Environmental Law & Justice Project; "The World Trade Center was built without the guidance of these typosof health and safety laws."
Dr. Chang, Professor of Environmental Medicine from NYU, reporting ontesting done by a team of scientists in the areas of Inhalation Toxicology,Neurotoxicology, Pulmonary & Critical Care, Epidemiology & Air Pollution. Please note: This data was extremely technical and difficult to comprehendin layman's terms. Dr. Chang was reluctant to translate this data ina way that might reveal his personal opinion about any of it, thoughhe did say more than once, 'we just don't know'. Here's the best I coulddo at deciphering it Dust samples taken from the ground at various locations in the areaof Ground Zero are comprised of mostly large particles: "Only a verysmail fraction of the dust conatins the most dangerous, microscopic particles." Samples showed: -- A very high pH factor, which is an irritant to the nose & upper respiratorytract. This causes discomfort but doos not present danger. •- A large concentration of lead, occassionally surpassing the EPA'ssafety standards -- A large concentration of carbon, often surpassing the EPA's safetystandards Dr. Chang also said his team and a similar team of scientists at PutgersUniversity hope they will have the funding necessary to continue monitoringthese levels for the duration of the WTC cleanup process.
There was an additional panelist, whose name & organisation I did notcatch. She was a Specialist in the area of Radioactive Contamination. Addressing the question of whether or not there is radioactive contaminationof the air, soil and water, she said; "...the probability is extremelyremote." This issue is monitored by both the Radiation Control Officeof the Department of Health and private, independent agencies.
Tammy Meltzer t ti. y. onebox.com, - email (212) 894-3750 x6038 - voicemait/fax
FREE voicemail, email, and fax...ali in one place. Sign Up Now! .http://ww onebo .,fors
t 0/121200). . 001l '1PS/S'i?t Ih0VU LGSi i<''t J. VV:! fC. O Al 1O0/fl/01
NYC-WTC-000117793
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000121258
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
13 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121287
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121138
Air monitoring report for 345 South End Avenue buildings conducted in December 2001 showing TEM results.
13 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121516
Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.
23 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121076
Air monitoring report for 345 South End Avenue buildings conducted in March 2002 showing TEM results.
12 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000124246
Laboratory results for confirmatory asbestos bulk sampling conducted on the roofs of 99 Church Street in May 2002.
15 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121364
Chain of custody for air samples collected at 345 South End Avenue buildings in late January and early February 2002.
12 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112249
Invoice for roof cleanup services involving asphalt and gravel removal totaling over $24,000 at 26 Wall Street.
10 shared non-person entities · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118332
Invoice dated July 31, 2002 detailing costs for asphalt and gravel roof cleanup at 60 Broad Street.
8 shared non-person entities · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121332
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
7 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000127341
Invoice from Fiber Control, Inc. dated July 2, 2002, billing the DEP for work at job sites including 119 Chambers Street.
9 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000126288
Invoice dated July 18, 2002, from Fiber Control Inc to the New York City Department of Environmental Protection for facade and other cleanup services.
6 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000155118
Correspondence regarding a joint meeting with building owners to discuss cleanup timelines, funding options, and EPA clearance requirements.
Cited alongside this record in an Ask answer
NYC-WTC_000168020
Detailed furniture specifications and pricing for the Mayor's Office of Emergency Management workspace on Floor 23 of 7 World Trade Center.
Cited alongside this record in an Ask answer
NYC-WTC_000095634
Memo dated January 10, 2005 regarding a SEQR Lead Agency request for the BMCC Decontamination project.
Cited alongside this record in an Ask answer
NYC-WTC_000141648
Memorandum instructing staff to submit monthly force account equipment usage reports for FEMA reimbursement.
Cited alongside this record in an Ask answer
NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer