NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 46/320 ALBANY STREET 000301, 16/7502
Document / 38 pages

HVAC and environmental inspection report for 350 Albany Street, Feb

Machine-extracted title · confidence 95%

Letter from Athenica Environmental Services detailing HVAC and environmental inspections conducted at 350 Albany Street in February 2003.

NYC-WTC_000116268–000116305

Folder label: “320 ALBANY STREET 000301, 16/7502

Page image
Scanned page image, NYC-WTC_000116288
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document Mechanical Exhaust System Visual Inspection Form Mechanical Exhaust System Identification: Location: MECHANKAL EXHAUST FAN 19 FccR - REOF-350ALBANYSTBEET Associated mechanical room: clean__ Y_ dry_Y N System Components INOTE: if component not present (NP), not found (NF) or inaccessible (I) please indicate in last column] Area Served: KITCHENS & BATHRDOMS stored chemicals/refuse Surface Dust/ Debris Present? Exhaust air outlet: Location: Accessible for inspection? Y N _(explain): - louvers. grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators - blower housing acoustical lining - vibration collars Exhaust air distribution: - Exhaust air ducts Est total In ft 60 Specify type (circle): No. locations inspected / brous glass lined meta masonry fbrous glass board flex-duct - Accessible in-line fire dampers - Accessible tuming vanes - Exhaust air grilles Other (specify): wood Est. total qty Est. total gty. Est. total oty No. locations inspected_ C No. locations inspected No. locations inspected_0 Other Information: • Y Y • Page 1 of1 N WTC Dust Present? Component • not present • not found • inaccessible Y Y NP NP I NP I : • General impression (indicate recommendations for cleaning based on finding of WTC dust): E IVTC RELATED DUST WAS EBSERVEA IN THE CEMPONENTS OF THE FAN ABCÍÉ AND BELCW THE LOUiFRS. - WTC RELATED DUST WAS OBGRVED NN THE DUCTWCRK, i - CIEANING FOR :WTC DEBRIS IS RICCHHENDED. EX CLEAN THE EXHAUST FAN UNIT AND AS ASSOCIATED DUCTWERK. KEY: NP = not present; NF = not found; I = inaccessible; U = unknown NYC-WTC_000116288

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116288Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →