NYC 9/11 Public Portal Document Mechanical Exhaust System Visual Inspection Form Mechanical Exhaușt System Identification: MECHANICAL EXHAUST FAN F76 Locationill 6 FLIDR- CROT 350 ALBANY STPEET Associated mechanical room: clean Y_ N dry_ _Y System Components [NOTE: if component not present (NP), not found (NF) or inaccessible (I) please indicate in last column] Exbaust air outlet: Location: Area Served: RTCHENS & BATHEDOHS _N stored chemicals/refuse Y _N Surface Dust/ Debris Present? WTC Dust Present? Accessible for inspection? Y N _(explain): - louvers. grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators - blower housing acoustical lining - Vibration collars Exhaust air distribution: - Exhaust air ducts Est total In ft 60 Specify type (circle): meta abrous glass lined meta No. locations inspected_ masonry ibrous glass board Rlex-duct wood - Accessible in-line fire dampers Est. total qty_ - Accessible turning vanes Est. total qty_ - Exhaust air grilles Est. total qty_ = No. locations inspected_o No. Locations inspected - No. locations inspectedO Other (specify): Y Y Other Information: Page 1 of 1 Component • not present • not found • inaccessible NP NP I NP I General impression (indicate recommendations for cleaning based on finding of WTC dust): - THe UNIT IS NOT WOPKING. - SOHE ATTEHPT TO CLEAN WAJ MADE, WTC REUATED DUST ABOVE THE LOUVeRS, BUT HEANY ACCUHULATION OF WTC DEBEIS WAS OBSERUED "BELOW THE LOUNERS. -WTC DEBAE WAS BBSEAVED IN THE COMPONENTS OF THE FAN AND ITS ASSOCIATED DUCTWORK - GEANING FOR WTC DEERIS IS RECOMHENDED.... - CIEAN THE EXHAUST FAN UNIT AND ITS ASSOCATED DUCIWORK KEY: NP = not present; NF = not found; I = inaccessible; U = unknown NYC-WTC_000116285

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116285Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →