NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual Tncnertinn Form PT 1 ..e Ventilation Syste den cation: - - - - ;. . Locaon: Area Serve. ,]M ii ouT' &d4 i E ,u oo Ky sit t to ODD ALIW n`ic - St.Og Associated mechanical room: clean Y N dry Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC • not present [NOTE: if component not present (NP), not found (NF) or inaccessible (I) please Debris Dust • not found indicate in last column] Present? Present? • Inaccessible Outside air intake: Location:

Accessible for inspection? Y i/ N (explain):

- louvers, grates and/or screens - outside air duct - outside air damper(s) Air handling unit: - outside air mixing chamber - filter rack(s) ti - filter media - blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators - blower housing acoustical lining - pre-heat coils - heating coils - cooling coils N - re-heat coils NP - condensate drain pan - supply air plenum - supply air plenum damper(s) - vibration collars Supply air distribution: - Supply air ducts Est. total In ft to No. locations inspected I Specify type (circle): eta] fibrous lass lined eta masonry fibrous glass board flex-duct wood . ) - Accessible in-line fire dampers Est total qty No. locations inspected_._ l~ - Accessible turning vanes Est. total qty No. locations inspected - In-line reheat/cooling coils Est. total qty No. locations inspected Supply air diffusers Est total qty_ No. locations inspected ; ' Return aiP distribution: Return air ducts Est. total In ft No. locations inspected Specify type (circle): metal fibrous glass lined metal ~masomy fibrous glass board flex-duct wood `' Iv p - Return air plenum Est. total RA plenum areas I No. locations inspected I - Return air plenum damper Est. total qty No. locations inspected - Accessible in-line fire dampers Est. total qty No. locations inspected NF - Accessible turning vanes Est. total qty No. locations inspected - Return air grilles Est. total qty ~ No. locations inspected

NYC-WTC-000116194

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116194Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →