WTC building inspection form, 320 Albany Street

Machine-extracted title · confidence 90%

Form documenting visual facade inspections and air monitoring status for a building at 320 Albany Street.

NYC-WTC_000116169–000116225

Folder label: “320 ALBANY STREET 000301, 16/7502

Page image
Scanned page image, NYC-WTC_000116187
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 22 Mechanical Exhaust System Visual Enspection Form Mecbanical Exhaust System Identification: HECHANICAL EXHAUST FAN#15 Location: MAIN ROOF — 300 ALBANY STREET Area Served: Associated mechanical roora: clean_ Y N cay N System Componeats INOTE: if compenent not present (NP), net found (NF) or inaccessible (*) please indicate in last column] Exhanst air outlet: Location: stored chemicals/refrse Accessible for inspection? Y N _(explain): - louvers, grates and/or screens - outside air duct - outside air damper(s) Exhaust far unit: - blower assembly incl. blower wheel, housing, air vanes, in-line noise attennators - blower housing acoustical lining - Vibration collars Exhaust air distribution: - Exhaust air ducts Est total In ft Specify type (circle): metal Lex-duct - Accessible in-line fire dampers - Accessible turning vanes - Exhaust air grilles 100 No. locations inspected_ 1 Mbrous glass lined meta! masonry fbrous pless board woOd Est. total qty Est. total qty Est. total qty. Other (specify): 9 No. locations inspected No. locations inspected No. locations inspected O Other Information: Surface Dusti Debris Present? Y Page 1 of 1 _N WTC Dust Present? Component • not present • not fomed • inaccessible NP NP Y NP NP I General impressien (indicate recommendatiens for cleaning based on finding of WTC dust): - WTC RELATED DUST WAS OBSERVED INTHE FAN AND ITS COMPONENTS, AND ITS ASSOCIATED DUCTS. - CLEANING 1S REQUIRED FOR WTC RELATED DUST. - CLEAN THE EXHAUSI FAN, ITS COMPONENTS AND ITS ASSOCIATED DUCTS. KEY: NP = not present; NF = not found; I = inaccessible; U = unkmown NYC-WTC_000116187

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116187Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →