.NOV.13..2002 4:22PM ROSS & HARDIES NO.979 P.11

A'

Application; This procedure utilizes wet methods and carefiil hygiene protocol for cleaning rooft contaminated with asbestos containing material(ACM), 1. The entire roof shall be considered the work area for entry/amass detenxninations. All abatement will be performed by NYSDOL licensed contractors with NYC DEP certified workers. For non gravel or stone covered roofs with localized accumulations of visible debris, the cleanup areas shall be specified ("specified area") by DEP. For gravel/stone covered roof surfaces, the entire roof shall be included in the specified roof area for clean-up. The gravel/stone shall be taken to a clean-up sta g area on the roof and washed. Water shall be collected, filtered, and discharged into the drain/sewer as applicable. 2. A changing area consisting of two adjacent step-off pads located on the roof immediately adjoining the roof entrance/exit. This area shall consist of a clean pad and a change pad. The clean pad shall be adjacent to the building interior access way (or at the point of entry to the roof for exterior access). The change pad shall be adjacent to the contaminated roof areas. Each pad (change pad and clean pad) shall consist of two layers of 10- rail reinforced plastic on the roof/acccss way surface and shall be large enough to facilitate changing and decontamuination as described herein, A minimum of 4' x 4' is recommend, though the exact configuration will be specific to the roof. i '• v 3, Workers shall fiat step from the building interior (or exterior at the point of entry to the roof) directly onto the clean pad. On the clean pad, each worker shall be double suited with disposable coveralls, plastic booties, gloves, and head ooverings. Rubber boots may be used instead of the plastic booties. The boots shall be wet wiped and HEPA vacuumed prior to leaving the roof. Each worker shall wear a ntinimurn of a half-fhsee sir- purifying respirator equipped with HEPA cartridges,

4. All penetrations at the roof within 10 feet of the specified roof area included in the clean-up shall be cleaned by wet methods;IWA vacuum and sealed with 5-mil polyethylene sbcctiag.

5. Roof cleanup shall begin at the, entrancelexit and proceed in a path working away from the entrance/exit. Water shall be the primary engineering control to minimize the potential for fiber release. 6. Roof surfaces shall be wetted and then wet cleaned using wet wiping techniques with water, mops, rags, brushes, etc. HEPA vacuuming may also be used as alternative to or in combination with wet cleaning. 7. Throughout the procedure, all personnel catering or existing the roof shall observe the personal decontamination practices. Attention shall be paid to limiting unnecessary walking on or disturbance of material on the goof These personal decontamination procedures shall be strictly adhered to, in order to minimize the potential for spreading contamination to the interior of the buildings. 8. Solid nonporous objects, such as metal patio f4trniture, plant potters, and plastic furniture cushions, shall 1e wet wiped with damp rags, Wooden objects such as decking shall be HE?A- vacuumed, wet wiped, and lightly brushed with a bristle brush utilizing simultaneous misting and local HEPA exhaust, Woven materials shall either be disposed as ACM or bagged and removed off-site for proper laundering in accordance with 29 CFR 1901, 1001. Potted plants with visual eon on should be disposed as ACM wastes unless the owner requests decontamination. Potted plants will be repeatedly rinsed, and provisions shall be made to catch the runoff water (i.e. into ACM disposal bags or by using rings and HEPA wet-vacuums). 9. After completion of the above, the specified area roof shall be carefully washed.

Page 3 05/03/02

NYC-WTC 000115610

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000115610Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →