NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 39/161/167 William Street; BN# 1001269 / 1001268
Document / 16 pages

Asbestos cleaning permit application cover letter, Sep 2002

Machine-extracted title · confidence 100%

Letter submitting executed license agreements for asbestos cleaning at a Lower Manhattan building to DEP.

NYC-WTC_000110854–000110869

Folder label: “161/167 William Street; BN# 1001269 / 1001268

Page image
Scanned page image, NYC-WTC_000110863
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document SEP-30-2002 12:33 NYCDEP BANHM ASBJLEAD TRU 718 595 3648 P.10

Roof CleanU

Application: This procedure utilizes wet methods and careful hygiene protocol for cleaning roofs contaminated with asbestos containing material (ACM).

1. The entire roof shall be considered the work area for entry/access determinations. All abatement will be performed by NYSDOL licensed contractors with NYC DEP certified workers.

For nongravel or stone covered roofs with localized accumulations of visible debris, the clean-up areas shall be specified ("specified area") by DEP.

For gravel/stone covered roof atafaces, the entire roof shall be included in the specified roof area for clean-up. The gravel/stone shall be taken to a cleanup staging area on the roof and washed. Water shall be collected, filtered and discharged into the drain/sewer as applicable.

2. A changing area consisting of two adjacent step-off pads located on the roof immediately adjoining the roof entrance/exit. This area shall consist of a clean pad and a change pad. The clean pad shall be adjacent to the building interior access way (or at the point of entry to the roof for exterior access). The change pad shall be adjacent to the contaminated roof areas. Each pad (change pad and clean pad) shall consist of two layers of 10- mil reinforced plastic on the rooflaccess way surface and shall be large enough to facilitate changing and decontamination as described herein. A mininuun of 4' x 4' is recommend, though the exact configuration will be specific to thereof. 3. Workers shall first step from the building interior (or exterior at the point of entry to the roof) directly onto the clean pad. On the clean pad, each worker shall be double suited with disposable coveralls, plastic booties, gloves, and head coverings. Rubber boots may be used instead of the plastic booties. The boots shall be wet wiped and HEPA vacuumed prior to leaving the roof. Each worker shall wear a minimum of a half-face air- purifying respirator equipped with HEPA cartridges.

4. All penetrations at the roof within 10 feet of the specified roof area included in the clean-up shall be cleaned by wet rnethods/HEPA vacuum and sealed with 6-mil polyethylene sheeting.

5. Roof cleanup shalt begin at the entrance/exit and proceed in a path working away from the entrance/exit. Water shall be the primary engineering control to minimize the potential for fiber release.

6. Roof surfaces shall be wetted and then wet cleaned using wet wiping techniques with water, mops, rags, brushes, etc. HEPA vacuuming may also be used as alternative to or in combination with wet cleaning.

7. Throughout the procedure, all personnel entering or existing the roof shall observe the personal decontamination practices. Attention shall be paid to limiting unnecessary walldng on or disturbance of material on the root These personal decontamination procedures shall be strictly adhered to, in order to minimize the potential for spreading contamination to the interior of the buildings.

S. Solid nonporous objects, such as metal patio furniture, plant potters, and plastic furniture cushions, shall be wet wiped with damp rags. Wooden objects such as decking shall be HEPA vacuumed, wet wiped, and lightly brushed with a bristle brush utilizing simultaneous misting and local HEPA exhaust Woven materials shall either be disposed as ACM or bagged and removed off-site for proper laundering in accordance with 29 CFR 1901. 1001. Potted plants with visual contamination should be disposed as ACM waste unless the owner requests decontamination. Potted plants will be repeatedly rinsed, and provisions shall be made to catch the runoff water (i.e. into ACM disposal bags or by using rags and HEPA wet-vacuums).

9. After completion of the above, the specified area roof shall be carefully washed.

Page 3 0S/03/02

SEP-30-2002 12 30 718 595 3648 99% P.10

NYC-WTC 000110863

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000110863Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →