NYC 9/11 Public Portal Document
New York Lab
307 West 38th Street, New York, NY 10018
Phone: 212-290-0051 Fax: 2122900058 Email:
Attn: Howard Bader Customer ID: HAB50
H.A. Bader Consultants Customer PO:
88 Bleecker St Received: 10/19/01 4:30 PM
Suite 4E
New York, NY 10012
Fax: (212) 477-8941 Phone: 212-475-4122 EMSL Order. 030106593
Project: DC37 / 115 Chambers Street, NY, NY EMSL Project ID:
Analysis Date: 10/20/2001
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
Non-Asbestos Asbestos
Sample Location Appearance Treatment % Fibrous % Non-Fibrous % Type
D111 - Basement File Gray Teased 20.00% Synthetic 30.00% Non-fibrous (other) None Detected
030106593-0011 Room Desk Fibrous Dissolved 50.00% Cellulose
Heterogeneous
D112 Basement Gray Teased 5.00% Synthetic 20.00% Non-fibrous (other) None Detected
030106593-0012 Cabinet by Fibrous Dissolved 75.00% Cellulose
Elevator Heterogeneous
D113 Field Blank White Teased 00.00% Non-fibrous (other) None Detected
030106593-0013 Non-Fibrous Dissolved
Heterogeneous
D114 Roof top Air Gray Teased 5.00% Min. Wool 90.00% Non-fibrous (other) None Detected
030106593-0014 Wandler East Fibrous Dissolved 5.00% Cellulose
Heterogeneous
D115 Roof top Air Gray Teased 5.00% Synthetic 82.00% Non-fibrous (other) None Detected
030106593-0015 Wandler West Fibrous Dissolved 3.00% Min. Wool
Heterogeneous 10.00% Cellulose
D116 2nd Floor Front Gray Teased 10.00% Min. Wool 75.00% Non-fibrous (other) None Detected
030106593-0016 window Ledge Fibrous Dissolved 15.00% Cellulose
Heterogeneous
D117 2nd Floor Front Gray Teased 5.00% Min. Wool 90.00% Non-fibrous (other) None Detected
030106593-0017 window Ledge Fibrous Dissolved 5.00% Cellulose
Heterogeneous
D118 2nd Floor Hepa Gray Teased 30.00% Synthetic 40.00% Non-fibrous (other) None Detected
030106593-0018 Unit Fibrous Dissolved 30.00% Cellulose
Heterogeneous
D119 1st Floor Hepa Gray Teased 3.00% Cellulose 97.00% Non-fibrous (other) None Detected
030106593-0019 Unit Non-Fibrous Dissolved
Heterogeneous
Dan Osborne
Analyst Laboratory Manager
or other approved signatory
PLM has been known to miss asbestos in a small percentage of samples which contain asbestos. Negative PLM results cannot be guaranteed. Samples reported as <1% or none
detected shotid be tested with TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL
Mal cal, md The above test must not be used by the client to claim product endorsement by NVLAP nor any agency of the United States Government
nalys ,erforrIed by EMSL Manhattan (NVLAP #101048.9), NY ELAP 11506
P nt unt- 2
NYC-WTC 000106181
OCR can misread numbers and units. Confirm readings against the page image before using them.