NYC 9/11 Public Portal Document
1
ATC Environmental, Inc.
I 104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/26/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED, and Energy-Dispersive X-RAY Spectroscopy
(SOS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Related, Tribeca T.R., 105 Duane St., NY, NY
I Various Sites
Date Received: 10/26/01
TEM Sample No.: 5769 -
Grid Openings Analyzed:
62531
6
Project Sample No. : 25 Average Grid Opening: 106.00 um
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
----------------------------------------------------------------------------------------------------------------------------------
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. truct. Filter Air
Fibers Bundles Clusters Struct. Struct. '=urn
Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures, 0 0 0.0 0.0000 0
Non-Asbestos 2 0 0 0 0 C 0.0 0.0000 N/A
No Identification 0 0 0 .. 0 0 0.0 0.0000 N/A
I Totals (All Structures)
Tae estimated uncertainty of this analysis is 1 standard oev:at:on.
0 ,. 0.0 0.0000 N/A
--------------------------------------------------------------------------------------- ------------------------------------------
Non-asbestos fiber i.d. (EDS/SAED): None detected -
Amphibole Asbestos Type: None detected
----------------------------------------------------------------------------------------------------------------------------------
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
I Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
1
NYC-WTC 000104249
OCR can misread numbers and units. Confirm readings against the page image before using them.