ATC Environmental, Inc.
I 104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vcl. 52, No 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Related, Tribeca T.R. 105 Duane St.. NY, NY TEM. Sample No.: 5761 - 62200
Various Sites
Date Received; 10/25/01 Grid Openings Analyzed: 6
Project Sample No.: 27 Average Grid Opening: 106.00 um
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
----------------------------------------------------------------------------------------------------------------------------------
FIBROUS PARTICULATES ANALYZED
I Single
Number Observed
Matrix Total.
Tota.
Struct.
CONCENTRATION
Filter Air
Fibers Bundles Clusters Struct Struct. =5u^ Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous C 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 2 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 3 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
----------------------------------------------------------------------------------------------------------------------------------
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
----------------------------------------------------------------------------------------------------------------------------------
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC 000104166