Fax cover sheet from JLC Environmental Consultants to DEP regarding 114 Liberty Street dated March 12, 2003.

NYC-WTC_000101393–000101395

Folder label: “JLC REPORTS

Page image
Scanned page image, NYC-WTC_000101394
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MAR. 12. 2003 5' 15PM JLC ENViRO'NMEN"AL NO. 425 P. 3 JLi tNVNUNMf;NTAL CONSULTANTS,(NC, 200 Park Avenue South,Suite 1001, New York, New York 10003 Phone:(212)420.8119 Fax:(212)420.8092 Pr ot No.: 03-2744 New York City D.B.P. FLAP Lab Code; 11029 Anaiyte: LEAD/ WIPE 69-17 Junction Blvd. NIOSH and AIHA Lab Code: 100273 Date Collected 313!2003 Flushing, NY 11373 NVLAP Lab Code: 101963 Date Received: 3/6/2003 Dale Analyzed: 318/2003 Batch C: 03031.328 Site: j 114 Liberty Street, New York, NY

SUMMARY OF ANALYTICAL RESULTS - DUST WIPE Sample0 Description!Location Area in Inches Lead Lab # (L x W) Concentration Client's Samole

1 12th Floor/ Lead Dust! Floor/ Kitchen 12x12 483.0 2592 01

2 42th Floor/ Lead Dust/ Weill Living Rooml Upper Left 12x12 <20 2593 02

3 12th Floor! Lead Dust/ Counter Top/ Kitchen 12x12 <20 2594 03

Samcdo Angivsia Bw Atomic Absorption Spectrometry (AAS) using an air-acetylene flame with background correction.

All samples were prepared and analyzed in accordance with the HUD 'Guidelines for the Evaluation end Control of Lead Based Paint Hazardous in Housing" Appendix 14.2 and the Environmental Protection Agency Method EPA SW84t3-30808420.

4 am Machhiwele Collected By: Shown Rajkumer Laboratory Director Analyzed By: Modell Collins

Mlnanum Deatecilon Limit 420 ug/f12 a

HUD'Guldelines for the Evaluation and Control of /sad-Based Paint Hazardous in Housing" 06/98: define the clearance standards, based on wipe oempling era: •40 ugftt2 for floors; '2311 ugttt2 for Interior window sg1s; '400 ugtffa for window and exterior concrete or other rough DISCLAIMER: JLC Environmental Consultants, Inc. did not colect the analyzed samples and thus accepts collection and/or maintenance, JLC roles on the event for all sample Information prior to aeibnery at JLC. no liability with regard to their

Page 1 of 1

NYC-WTC 000101394

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000101394Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →