Asbestos contractor permit application, 114 Liberty Street, Oct 2001

Machine-extracted title · confidence 90%

Permit application for a licensed asbestos contractor to clean interior dust at the unoccupied 114 Liberty Street building.

NYC-WTC_000100686–000100689

Folder label: “114 LIBERTY STREET 1001041, 52/7502

Page image
Scanned page image, NYC-WTC_000100689
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

oiFl Cleaning Procedures For

(21) After successful clearance air monitoring, isolation barriers shall be removed in accordance with the applicable requirements of Title 15, Chapter 1 of the RCNY.

(22) The cleaning contractor is not responsible for damage or loss caused by the acts of parties not involved with the cleanup. Tenant shall be responsible for the removal of any valuables. If such removal is not feasible, the tenant shall notify the Project Monitor in writing (including original receipt, formal appraisal, or estimated value) as to the location, description and value of said item.

(23) Disposal of wastes generated during the cleaning shall be the responsibility of the contractor. All all

waste generated shall be treated as asbestos-containing material (ACM). Transportation and disposal of generated waste shall be in compliance with all applicable rules and regulations.

(24) All work shall be in compliance with all other applicable requirements of Title 15, Chapter 1 of the RCNY.

(25) The following table contains special conditions and handling instructions for items in specific units. Items not specifically referenced in this table shall be handled in accordance with the procedures specified in this scope of work.

Floor No. Action Item / Notables 5th A artition/ barrier shall be installed at the damaged north wall. 4th A artition/ barrier shall be installed at the damaged north wall and ceiling. Commercial space: The HVAC system, associated ductwork and suspended ceiling shall be 3rd removed and discarded. I St The HVAC system and associated ductwork, and stove exhaust ducts shall be removed and discarded.

(26) Time sheets shall be submitted to DEP on a weekly basis.

(27) At the completion of work a final report shall be submitted to DEP. The final report shall include copies of the daily logs (activities and entry/exit logs), waste manifests, etc.

4 of 4

NYC-WTC 000100689

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000100689Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →