NYC 9/11 Public Portal Document
Cleaning Procedures
For
(7) A separate worker and waste decontamination enclosure system in compliance with Title 15,
Chapter 1 of the RCNY shall be installed at the entrance to each work area. Each work area shall
entail isolating three floors at 125 Cedar Street simultaneously. More than one work area may be
established. Work shall proceed from the penthouse down to the first floor. The use of a remote
decontamination enclosure system installed on the second floor for use at each work area (except
first floor and basement) may be acceptable. Prior approval must be received from the NYCDEP
for decontamination enclosure system placement and phasing of clean-up activities.
(8) An entry/exit log in compliance with the requirements set forth in Title 115, Chapter 1 of the
RCNY shall be maintained in the clean room. An activity log shall also be maintained by the site
supervisor.
(9) Initially, the interior of the elevator shaft, including the top of the elevator car and the elevator
pit, shall be HEPA vacuumed and wet wiped to allow for the use of the elevator during the clean
up. Once the clean up throughout the building is complete, the elevator shaft, including the top
of the elevator car and the elevator pit, shall be re-cleaned prior to clearance air monitoring.
(10) Isolation barrier locations (i.e.: wall or ceiling penetrations, windows, vents, doors, etc.) shall be
HEPA vacuumed and wet wiped prior to installing two-layers of 6-mil polyethylene sheeting and
sealed with tape. Terraces, window wells, and window guards that are accessible from the
interior shall be cleaned,.
(11) Negative pressure ventilation equipment shall be installed and operated continuously 24 hours
per day during all clean-up activities. Equipment shall run continuously until clearance air
monitoring. A minimum of one air change every 15 minutes shall be provided. When ducting to
the outside is not possible, a second negative air unit compatible with the primary unit may be
connected in series.
(12) A staging area shall be established within each unit for cleaning the surfaces of moveable items.
(13) All debris and/or dust shall be misted and double bagged. Accumulation of water is prohibited.
Water misting shall be sufficient to wet the material without water accumulations. Caution shall
be taken to avoid wetting items that may be damaged by wet methods. An encapsulating agent
shall not be applied. Once all surfaces have been wet wiped and HEPA vacuumed a second
cleaning shall be performed. Surfaces include but are not limited to walls, floors, ceilings, ledges,
windowsills, trims, appliances, equipment, personal items, and furnishings.
(14) Surfaces that may not be wet wiped shall be HEPA vacuumed three times or disposed as ACM
waste. Disposal of material may not occur without prior authorization by the building owner
and/or tenant, as applicable. Items identified by tenants for cleaning that cannot be cleaned shall
be immediately brought to the attention of DEP. DEP will contact the tenant or tenant
representative to resolve the issue. Any agreement to dispose the item(s) must be received in
writing from the tenant.
2 of 6
NYC-WTC 000097167
OCR can misread numbers and units. Confirm readings against the page image before using them.