NYC 9/11 Public Portal Document
10/16/2002 15:23 FAX 212 353 8306 ATC 2018
Attn: Benjamin SaUemi Received: 10/9/02 100:00 ?M
ATC Associates Inc. ATC Group tf: 8950
104 East 25th Street Analysis Date: 10/14/02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-8280
Project: DEP Glean-up ATC Project 4; 22904-0002
125 Cedar Street, New York, NY -
EPA PCMe Method Via Transmission Electron Microscopy
Noe Asbestos EPA PCMe
Asbestos ?CM Asbestos Asbaafos % of (TEM)
Sample Volume Fibers F/cc Type~(c) Fibers total F/cc Nales
A 1 50 3600.00 8 0.00 t None Detected 0 .0 <0.0002, Cellulose - 5 Struduios, Gypsum - 3 Structures
8950 -48
ROMAN PEY V MICHAEL A. GORYCKI, P.D.
Analyzed by: f Approved by! — --
ATC is not responsibie for dam reported In fioers/cc, wrhidr Is Ispendent on volun a collected by bo%tory personnel, The above report relates ony to the items tested, This
report may notbe reproduced, except in full ditout wrdtgn. approval by ATC Associates Inc.
Analysis performed by ATC Assodates Inc. (NV I,AP #10e79).
Forty Grid Openings tran each of the samples were exarninec for st etures greater than 5}tin length and nsvirsg a length-to-wleth mtlo greater.tnen 3:1
Wednesday, October 76, 2r702 Page 6 of 6