NYC 9/11 Public Portal Document 10/16/2002 15:22 FAX 212 353 8306 ATC 1 017

Attn: Benjamin Sallemi Received: 1019/02 1:00:00 PM A'TC Associates Inc. ATC Group #: 8950 104 East 25th Street Analysis Date: 10114/02 New York NY 10010 Fax: (212) 353-3599 Phone: (212) 353-8280 Project: DEP Clean-up ATC Project #: 22906-0002 125 Cedar Street,'New York. NY

EPA PCMe Method Via Transmission Electron Microscopy Noe Asbestos EPA PCMe Asbestos PCM Asbestos Asbestos % of (fEM) SaM,rple Volume FTher P/ec Typd(s) nbers sore! F/cc Notes

A 2S 40 3600.00 11 1 0.001 None Detected 0 0 <0.0002 Cell lose -10 Structures, Gypsum - 1 d950 -38 Structure

A 2S 41 3600.00 7 0.001 None Detected 0 3 <0.0002 Cellulose .3 Structures, Gypsum -4 Structures 8950 -39

A 2S 42 3600.00 10 0-00) None Detected 0 0 <0.0002 Cellulose - 7 Strucu.es. Gypsum -3 8950 -40 Structures

A 2543 3600.00 7 0.001 None Detectsd 0 0 <0.0002 Cellulose - 7 Struccres 8950 -41

A 2N 44 3600.00 8 0.001 None Detected 0 0 <0,0002 Cellulose -6 Structures. Gypsum -2 Structures d950 -42

A 2N 45 360000 8 0.001 None Detected 0 0 <0.0002 Cellulose -5 Structures, Gypsum -3 Structures 8950 -43 ..__. A 2N 46 8950 -44 3600.00 9 0.001 None Detected 0 0 <0.0002 Cellulose • 4 Structures, Gypsum - 4 Structures, Glass -1 Structures

A 2N 47 3600.00 10 0.002 None Detected 0 0 <0.0002 Cellulose - 9 Strucures, Gypsum - t SUvcturo 8950 -4S

A 2N 48 3600.00 14 0.001 CHRYSOTILE 2 13 0.0005 Celtulos - 8 Strunures, Gypsum - 5 8930 -46 Structures, Glass-1 Structure

A 2 49 3600,00 20 0-001 None Detected 0 0 <0.0002 ' Cellulose -12 Structures. Gypsum•8 8950 -47 Svuelures .

OV MI HAEL A. GORYCKI, Ph.D. ROMAN PEYS Analyzed by: / Approved by;

AC is not responsible icr data reported in flbers/cc, which is dependent on volume corected by non-laboratory personnel. The above report relates ony to the items tested. This report may not be reproduced, except in hull, w toit vaulter approval by ATC Assedates Ire. Analysis performed by ATC Assodstes Inc. (NY ELAF #106781. Forty Grid Openings from each of the samples were examined for structures greater then Spin length and having a Iength•to•width ratio greater than 3:t

Wednesday. October 16, 2002 Page 5 rrf 6

NYC-WTC 000097128

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000097128Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →