NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 02/201 WARREN STREET Block: 16 Lot: 220
Document / 53 pages

Health and safety plan Part II, 30 Warren Street, January

Machine-extracted title · confidence 100%

Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.

NYC-WTC_000096623–000096675

Folder label: “201 WARREN STREET Block: 16 Lot: 220

Page image
Scanned page image, NYC-WTC_000096657
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Regulatory Submittal Part III — Health & Safety Plan Fiterman Hall — 30 West Broadway, New York, New York Airtek Project 05-0867 —January 10, 2006

Level D personal protective clothing and equipment for excavation activities includes:

• Coveralls • Hard hat • Chemical resistant, ANSI approved safety shoes/boots • Work gloves • Safety glasses* (ANSI Approved) • Dust mask (optional) • Hearing Protection, as necessary

Level C protective clothing and equipment includes:

• Full-face powered air-purifying respirator (PAPR) with HEPA filter approved by the National Institute for Occupational Safety and Health (NIOSH)/Mine Safety and Health Administration (MSHA)1. Half-face air-purifying respirators (APR) may be used during work preparation activities. • Gloves - nitrile inner; chemical resistant outer (nitrile or neoprene) • ANSI-approved safety boots • Safety glasses* (ANSI Approved) • ANSI-approved Hard hat with bill facing forward • Tyvek coveralls with head cover (Two layers Tyvek or equivalent) • Water-resistant overboots which are treaded to provide slip protection • Hearing protection (as necessary)

Level B PPE may be required during jack hammering concrete unless'engineering controls are instituted incorporating local mechanical exhaust ventilation at the point of dust generation and will be required until personal air monitoring confirms that the level of silica is below the OSHA action level. Level B PPE consists of the following:

• Self-Contained Breathing Apparatus (SCBA) or combination airline/SCBA approved by the National Institute for Occupational Safety and Health (NIOSH)/Mine Safety and Health Administration (MSHA). • Gloves - nitrile inner; chemical resistant outer (nitrile or neoprene) • ANSI-approved safety boots • Safety glasses* (ANSI Approved) • ANSI-approved Hard hat with bill facing forward • Tyvek coveralls with head cover (Two layers Tyvek or equivalent) • Water-resistant overboots which are treaded to provide slip protection • Hearing protection (as necessary)

Level A PPE Use of this type of PPE is not anticipated at this site. Should work conditions and personnel sampling exceed action levels for a PPE upgrade to Level A, operations shall cease in that area until site conditions can be re-evaluated by the Contractor and the Environmental Consultant's CIH.

*Eye protection includes safety glasses, safety goggles, welding goggles, welding hoods, or full-face respirators. Prescription or non-prescription eyeglasses and sunglasses are not approved for eye protection. All acceptable eye protection must include side shields and must be ANSI-approved.

35

NYC-WTC 000096657

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000096657Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165900 · Box 7DDC

Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.

Cited alongside this record in an Ask answer

Compare copies and versions →