Regulatory Submittal Part III — Health & Safety Plan Fiterman Hall — 30 West Broadway, New York, New York Airtek Project 05-0867 — January 10, 2006

Level D personal protective clothing and equipment for excavation activities includes:

• Coveralls • Hard hat • Chemical resistant, ANSI approved safety shoes/boots • Work gloves • Safety glasses* (ANSI Approved) • Dust mask (optional) • Hearing Protection, as necessary

Level C protective clothing and equipment includes:

• Full-face powered air-purifying respirator (PAPR) with HEPA filter approved by the National Institute for Occupational Safety and Health (NIOSH)/Mine Safety and Health Administration (MSHA)l. Half-face air-purifying respirators (APR) may be used during work preparation activities. • Gloves - nitrile inner; chemical resistant outer (nitrile or neoprene) • ANSI-approved safety boots • Safety glasses* (ANSI Approved) • ANSI-approved Hard hat with bill facing forward • Tyvek coveralls with head cover (Two layers Tyvek or equivalent) • Water-resistant overboots which are treaded to provide slip protection • Hearing protection (as necessary)

Level B PPE may be required during jack hammering concrete unless engineering controls are instituted incorporating local mechanical exhaust ventilation at the point of dust generation and will be required until personal air monitoring confirms that the level of silica is below the OSHA action level. Level B PPE consists of the following:

• Self-Contained Breathing Apparatus (SCBA) or combination airline/SCBA approved by the National Institute for Occupational Safety and Health (NIOSH)/Mine Safety and Health Administration (MSHA). • Gloves - nitrile inner; chemical resistant outer (nitrile or neoprene) • ANSI-approved safety boots • Safety glasses* (ANSI Approved) • ANSI-approved Hard hat with bill facing forward • Tyvek coveralls with head cover (Two layers Tyvek or equivalent) • Water-resistant overboots which are treaded to provide slip protection • Hearing protection (as necessary)

Level A PPE Use of this type of PPE is not anticipated at this site. Should work conditions and personnel sampling exceed action levels for a PPE upgrade to Level A, operations shall cease in that area until site conditions can be re-evaluated by the Contractor and the Environmental Consultant's CIH.

*Eye protection includes safety glasses, safety goggles, welding goggles, welding hoods, or full-face respirators. Prescription or non-prescription eyeglasses and sunglasses are not approved for eye protection. All acceptable eye protection must include side shields and must be ANSI-approved.

35

NYC-WTC 000095815

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000095815Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165900 · Box 7DDC

Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.

Cited alongside this record in an Ask answer

Compare copies and versions →