NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 02/201 WARREN STREET Block: 16 Lot: 220
Document / 25 pages

Remediation plan cover page, 30 Warren Street, January 2006

Machine-extracted title · confidence 85%

Cover page for a remediation and deconstruction plan prepared for the State of New York.

NYC-WTC_000096519–000096543

Folder label: “201 WARREN STREET Block: 16 Lot: 220

Page image
Scanned page image, NYC-WTC_000096527
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Regulatory Submittal Part IV- Waste Sampling & Management Plan Fiterman Hall 30 West Broadway, New York, New York Airtek Project 05-0867 — January 10, 2006

the PPE and consumables will be recorded to assist in ensuring that sampling will be representative.

4.3 Deconstruction Waste

As noted in Section 4.1 above, dust characterization for hazardous waste characteristics will be performed. If dust classification sampling indicates that the dust is not a characteristic hazardous waste, and then by extension, any non-hazardous materials potentially impacted by dust (i.e., the Deconstruction Waste listed in subsection 2.3 above) would also not be hazardous. Where analyses indicate that the dust exceeds RCRA criteria for any one RCRA characteristic, deconstruction waste materials potentially impacted by the dust, as determined by the Environmental Consultant will be assumed to exceed that specific RCRA characteristic unless testing proves otherwise.

Within any floor of the building where dust exhibits RCRA-regulated levels of contamination, representative composite sampling of deconstruction waste will be conducted. Analyses will be for only the specific RCRA characteristic that was noted in the dust characterization study.

4.4 Universal Waste

Universal waste items will not be tested, but will be cleaned of dust by the application of HEPA-vacuuming and wet-wiping procedures prior to containerization.

4.5 PCB Waste

All ballasts, including those labeled "No PCB" will be containerized for disposal as PCB waste due to the presence of potting material. Potentially PCB-containing equipment other than ballasts, will be inspected and sampled as required to determine'=whether the dielectric fluid contains more than 50 parts per million (ppm) PCBs, which would make the equipment subject to the PCB regulations. As required by the NYS Education Department, representative samples of caulking material will be collected and analyzed prior to the deconstruction, and will be tested to determine the concentration of PCBs.

4.6 Miscellaneous Contefits

Initial characterization has been conducted by review of existing labels and/or Material Safety Data Sheets (MSDSs), as noted in the Chemical Log included in Attachment A. Specific requirements beyond initial characterization are found in the applicable federal, state and city solid and

NYC-WTC 000096527

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000096527Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →