NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 02/30 WEST BROADWAY Block: 127 Lot: 1
Document / 1 page

Bulk Asbestos Analysis Results, 30 West Broadway, May 2002

Machine-extracted title · confidence 100%

SciLab report summarizing bulk asbestos analysis results for samples from 30 West Broadway.

NYC-WTC_000096227

Folder label: “30 WEST BROADWAY Block: 127 Lot: 1

Page image
Scanned page image, NYC-WTC_000096227
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SciLab Job#: 202052278 Page 1 of 1 Client Name: Applied Technology Services, Inc. Table I Summary of Bulk Asbestos Analysis Results E02411

SciLab Client HG Sample Heat Acid Insoluble Sample Sample# Area Weight Sensitive Soluble Non-Asbestos ** Asbestos % by ** Asbestos % by # Location (gram) Organic % Inorganic % Inorganic % PLMIDS TEM

01 16-051302-01 0.202 13.86 69.80 16.24 NAD Chrysotile Trace E. Wall Sill Heay Dust - Grids 02 16-051302-02 0.314 27.07 41.72 31.11 NAD Chrysotile Trace Floor Opposite Water Fountains 03 16-051302-03 0.267 17.23 62.55 20.12 NAD Chrysotile Trace Desk 04 16-051302-04 0.369 13.28 67.21 19.41 NAD Chrysotile Trace North Sill

Analyzed by: Aleksandr Barengolts ;Date Analyzed 5/14/02 Quantitative Analysis (Semi/Full); Bulk Asbestos Analysis - PLM by EPA 600/M4-82-020 per 40 CFR (NVLAP Lab#200546-0); TEM (Semi/Full) by EPA 600/R-93/116 (not covered by NVLAP Bulk accreditation); or ELAP 198.1/198.4 for New York samples (NYSDOH ELAP#11480); NAD = no asbestos detected during a quantitative analysis; NA = not analyzed; Trace = <1%; Quantitation for beginning weights of<O.l grams should be considered as qualitative only; Qualitative Analysis: Asbestos analysis results of "Present" or "NVA = No Visible Asbestos" represents results for Qualitative PLM or TEM Analysis only (no accreditation coverage available from any regulatory agency for qualitative analyses); AIHA Lab#102843. Warning Note: PLM limi tion, only TEM will resolve fibers <0.25 micrometers in diameter. TEM bulk analysis is representative of the fine grained matrix material and may not be representative of non-uniformly dispersed debris for whiff 1 PLM evaluates is rec9mmende¢ (i.e. soils and other heterogenous materials).

Reviewed By

NYC-WTC 000096227

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000096227Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →