SciLab'Job#: 201112060
Client Name: Applied Technology Services, Inc.
Table I
Summary of Bulk Asbestos Analysis Results
HG Sample Heat Acid Insoluble
SciLab Client Asbestos
Area Weight Sensitive Soluble Non-Asbestos Asbestos by
Sample Sample# TEM by
# Location (gram) Organic % Inorganic % Inorganic % PLM/DS
---- ---- NA NVA
01 24110901-07 ' --- ---•
Across Member Dept. Next To Electric Box - 1st Fl Lobby
---- ---- NA NVA
02 24110901-08 ---- ---•
Conf. Rm Under Mirror R/S From The Door- 2nd Fl Conf. Rm Chrysotile Present
---- ---- ---- ---- NA
03 24110901-09
Reception Rm SE Corner On Top Of The Metal Handle
---- ---- NA NVA
04 24110901-10 ---- ----
4th Fl So. Conf. Rm On Top Of The Sculpture Of Lincoln
---- ---- NA Chrysotile Present
05 24110901-11 ---- ----
Inside Membership Dep. 5FF Rigt From The Door
--- ---- NA NVA
06 24110901-12 ---- ----
Inside Conference Rm 10 Ft From The Door Left
---- ---- NA Chrysotile Present
07 24110901-13 ---- ----
3rd F1 Reception Rm Under The Desk NE Corner
---- ---- NA Chrysotile Present
08 24110901-14 ---- ---
4th Fl So. Conf. Room Corner Next To Firepl ce
Analyzed by: Lance Tuckruskye A^ ; Date Analyzed: 11/12/01
ELAP PLM Analysi
Bulk Asbestos Analysis by EPA 600IM4-82-020 per 40 CFR 763 (NVLAP Lab #200546-0) and
*NAD/NSD = no asbestos detected; NA = not analyzed; NA/PS = not analyzed/ positive stop; PLM reliable in detecting asbestos in floor coverings
Protocol 198.4 for negative NY NOB samples: Note: PLM is not consistently
Protocol 198.1 for New York samples (NYSDOH ELAP Lab # 11480); FLAP TEM Analysis non-asbestos -containing in New York State (also see
be used to determine if this material can be considered or treated as
and similar non-friable organically bound materials. TEM is currently the only method that can be reproduced except in full without the approval of
Technology Accreditation requirements mandate that this report must not
EPA Advisory for floor tile, FR 59, 146, 38970, 8/1/94). National Institute of Standards and
the laboratory. This PLM report relates ONLY to the items tested.
AIHA# 102843; VT Cert# L01~ NVA=No Visible Asbestos
Reviewed By: