SciLab Job #: 201112059
Client Name: Applied Technology Services, Inc.
Table I
Summary of Transmission Electron Microscopy (TEM) Results for Asbestos (air)
14 Vesey Street
Structure Structure
Air Area * Analytical Asbestos Structures Detected Density Concentration Type
SciLab Client Dilution Filtered Analyzed Sensitivity (Microns) (struc/sq. mm.) (struc/cc air) of
Sample # Sample # Factor (liters) (sq. mm.) (struc/cc air) 0.5-5.0 >5.0 Total >5.0 Total >5.0 Total Asbestos
01 2411090101 744 .1 0.0052 0.0 0.0 0.0 <10 <10 <0.0052 <0.0052 NSD
1st Floor Lobby Next To Exit Right Side
02 2411090102 750 .1 0.0051 0.0 0.0 0.0 <10 <10 <0.0051 <0.0051 NSD
2nd Floor Conference Room Across Auditorium North Wall Next To Exit
03 2411090103 744 .1 0.0052 0.0 0.0 0.0 <10 <10 <0.0052 <0.0052 NSD
3rd Floor Lobby Next To Emergency Exit
04 2411090104 720 .1. 0.0053 0.0 0.0 0.0 <10 <10 <0.0053 <0.0053 NSD
4th Floor Lobby NE Comer
05** 24110901 05
Field Blank
06** 24110901 06
Field Blank
concentration represented by the detection of I structure
** not analyzed 11/12/01
NSn: No Asbestos Structures Detected Reviewed By: ; Analyzed By Date: