Environmental Characterization Report
Fiterman Hall, 30 West Broadway, New York, NY
Airtek Project #05-0867 — January 10, 2006
Personal exposure monitoring was conducted in strict accordance with published sampling and
analytical methodologies. These included National Institute for Occupational Safety & Health
(NIOSH) and Occupation Safety & Health Administration (OSHA) sampling protocols. Analytes
included Asbestos and the Contaminants of Potential Concern (CoPCs), as defined by the U.S.
EPA's COPC Committee. These include Silica, Polycyclic Aromatic Hydrocarbons (PAHs),
Dioxin, Polychlorinated Biphenyls (PCBs), Heavy Metals (Barium, Beryllium, Cadmium,
Chromium, Copper, Lead, Manganese, Nickel, and Zinc), and Mercury.
To measure personnel exposure to airborne contaminants workplace air is sampled over an 8-hour
period, or for the full work shift. Data from this sampling is calculated into an 8-hour time
weighted average (TWA) for comparison to established worker exposure guidelines. An Airtek
Industrial Hygienist observed and recorded general information about personnel work processes
conducted during the sampling. Site workers were asked to voluntarily wear personal monitors to
assess COPC exposure during site characterization field work.
43 Exterior Dust Investigation
As further described in the companion document Facade Characterization Report, a close visual
inspection was conducted of the building façade as a part of an assessment of the need for
exterior cleaning of the facade. In addition to visual inspection, wipe sampling of facade surfaces
was conducted to assess residual heavy metals surface concentrations as an illustration of overall
conditions.
Airtek environmental technicians collected heavy metals wipe samples from representative exterior
surfaces at the 14th Floor Setback, the 5`h floor setback, and at ground level. Samples were collected
in accordance with the NIOSH 9100 dust wipe protocol for lead sampling. Wipe sampling was
carried out in a carefully controlled manner in order to ensure the validity of the results. The samples
were taken with commercially available "ghost-wipes." The area sampled was a precisely measured
surface area. Careful precautions were taken in order to avoid cross contamination of samples and to
keep track of sampling locations. The measurements and locations of the samples collected were
10
NYC-WTC 000095697
OCR can misread numbers and units. Confirm readings against the page image before using them.