NYC-WTC_000121364
Chain of custody for air samples collected at 345 South End Avenue buildings in late January and early February 2002.
15 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
NYC-WTC_000095478–000095630Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
sample and sent it to the If any dust and/or debris was found in the apartment we collected a bulk laboratory for analysis.
If no sample could be taken due to insufficient material present at the time we were in the apartment, the inspector documented this on the log.
4.2 Air Sampling Procedures
ALC's licensed technicians collected air samples using TEM Methodology. The technician collected five (5) air samples on each floor. The samples were taken in three (3) apartments and at two separate areas in the hallways on each floor. The technician identified the locations that appeared to contain the most visible dust and debris to perform sampling. t
in The air samples were collected using high volume air sampling pumps. Once the pumps were place the air sampling technician recorded the location, time, date, sample numbers, pump number. flow rate, start and stop times and his initials. motor The air cassette was independent of the pump motor. This is to prevent the vibrations of the stand or tripod was used to hold the cassette in from affecting the fibers in the cassette. A separate degrees downward from the horizontal stand. This is to insure place. The cassette was angled 45 that no asbestos will drop into the cassette while sampling.
Using a rotameter, we calibrated each pump to the required flow rate,-noting this rate on the pump sample record. After calibrating the pumps, the end cap from the cassette was removed; the was turned on and run for the required amount of time.
The sampling pumps were checked periodically to ensure they were still operating, the cassettes were still in place, and no one has disturbed the equipment. If at any time the area being sampled was suspected of having high fiber counts, the filter inside the cassettes were examined for "overloading", or an excessive amount of fibers and/or debris on the filter.
When the pre-determined volume of air has been collected, the technician then calibrated the • sampling pump again to determine the current flow rate. This rate will often be different from the flow rate measured at the beginning of the sampling period. That difference is usually due to the clogging of the filter, thereby adding increased resistance to the flow of air.
Once the pre-determined volume of air has been reached, the time was recorded as well as on the cassette. Before the pump was turned off, the cassette was angled upward and the cap replaced and the end plug. The cassettes were placed in sealed containers, labeled with an identifying code and a sample log was kept. The samples were then submitted to the laboratory to be analyzed for asbestos content. A chain of custody record was prepared and accompanied the samples to the laboratory.
4.3. Asbestos Analysis and Methodology
Each air sample is cross-referenced by field designation and lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within a HEPA Filter clean bench to avoid any possible contamination. Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. Samples collected represent the typical airborne fiber concentration of the area.
NYC-WTC 000095483
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000121364
Chain of custody for air samples collected at 345 South End Avenue buildings in late January and early February 2002.
15 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121258
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
16 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121076
Air monitoring report for 345 South End Avenue buildings conducted in March 2002 showing TEM results.
15 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121516
Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.
40 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117723
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
27 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
32 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121138
Air monitoring report for 345 South End Avenue buildings conducted in December 2001 showing TEM results.
18 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121287
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
14 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
32 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
35 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗32 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
28 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000095208
Documentation tracking the chain of custody for environmental samples collected from Building #400 at 375 South End Avenue in October 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095331
Chain of custody form documenting bulk sampling and air monitoring at 375 South End Avenue on November 17, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117723
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121516
Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000095208
Documentation tracking the chain of custody for environmental samples collected from Building #400 at 375 South End Avenue in October 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000095331
Chain of custody form documenting bulk sampling and air monitoring at 375 South End Avenue on November 17, 2001.
Cited alongside this record in an Ask answer
Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000131925
Invoice from JLC Environmental Consultants for air monitoring services at 114 Liberty Street in March 2003.
Cited alongside this record in an Ask answer
NYC-WTC_000100789
Laboratory analysis results for asbestos content in beige bulk samples collected from a pizzeria on one of the building floors.
Cited alongside this record in an Ask answer