apartment we collected a bulk sample and sent it to the
If any dust and/or debris was found in the
laboratory for analysis.
material present at the time we were in the
If no sample could be taken due to insufficient
apartment, the inspector documented this on the log.
4.2 Air Sampling Procedures
Methodology. The technician
ALC's licensed technicians collected air samples using TEM
The samples were taken in three (3) apartments and at
collected five (5) air samples on each floor.
on each floor. The technician identified the locations that
two separate areas in the hallways
appeared to contain the most visible dust and debris to perform sampling.
pumps. Once the pumps were in
The air samples were collected using high volume air sampling
date. sample numbers, pump number,
place the air sampling technician recorded the location, time,
• flow rate, start and stop times and his initials.
to prevent the vibrations of the motor
The air cassette was independent of the pump motor. This is
or tripod was used to hold the cassette in
from affecting the fibers in the cassette. A separate stand
horizontal stand. This is to insure
place. The cassette was angled 45 degrees downward from the
that no asbestos will drop into the cassette while sampling.
required fl ow rate, noting this rate on the
Using a rotameter, we calibrated each pump to the
sample record. After calibrating the pumps. the end cap from the cassette was removed: the pump
was turned on and run for the required amount of time.
ensure they were still operating, the cassettes
The sampling pumps were checked periodically to
equipment. If at any time the area being sampled
were still in place, and no one has disturbed the
inside the cassettes were examined for
was suspected of having high fiber counts, the filter
filter.
"overloading", or an excessive amount of fibers and/or debris on the
technician then calibrated the
When the pre -determined volume of air has been collected, the
the current flow rate. This rate will often be different from the
sampling pump again to determine
period. That difference is usually due to the
• flow rate measured at the beginning of the sampling
of air.
clogging of the filter, thereby adding increased resistance to the flow
time was recorded as well as on the
Once the pre -determined volume of air has been reached, the
cassette was angled upward and the cap replaced
cassette. Before the pump was turned off, the
placed in sealed containers, labeled with an identifying code
and the end plug. The cassettes were
samples were then submitted to the laboratory to be analyzed for
and a sample log was kept. The
custody record was prepared and accompanied the samples to the
asbestos content. A chain of
laboratory.
4.3. Asbestos Analysis and Methodology
internal code to ensure proper,
Each air sample is cross-referenced by field designation and lab
consistent handling through a chain of custody. Sample preparation takes place within a HEPA
any possible contamination. Air sampling was conducted at a level
Filter clean bench to avoid
during normal
approximating the breathing zone of persons anticipated to be present in the area
concentration of the area.
operations. Samples collected represent the typical airborne fiber
NYC-WTC 000095336