Air monitoring report cover sheet, 345 South End Ave, 2001

Machine-extracted title · confidence 90%

Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.

NYC-WTC_000095478–000095630

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100

Page image
Scanned page image, NYC-WTC_000095630
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC DEP Mr. Krish Radhakrishnan, P.E. Director 59-17 Junction Boulevard, 8" Floor Corona, NY 11368-5107 Via Facsimile

Subject: Final Air Clearance Sampling: Gateway Plaza 355 Southend Avenue Building 200: Apartments-23F, 22F, 34D.19H,17B,16F

Dear Mr. Radhakrishnan. P.E.

Please find enclosed the third party air monitoring report performed at selected locations of the above referenced location. Upon completion of the asbestos clean up procedures, a visual inspection was conducted in the work areas located in the in the specific apartments of the 200 building of the Gateway Plaza. Since no visible asbestos containing material (acm) or debris was seen, final air clearance sampling was then conducted.

The air sampling and analysis were done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE II AHERAJASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

The air samples were collected by Alvin B. Blake a licensed sampling technician (AH#01-03528) under the supervision of Americo Rodriguez Jr., a licensed project monitor (AH# 89-07160)

ATC Associates (ELAP #10879) analyzed the samples using the Transmission Electron Microscopy (TEM) Methodology. The results indicated that the work areas achieved the acceptance criteria of at or below <0.01 fibers per cubic centimeters set by the above regulations.

If you have any questions and/or comments please contact us directly at 212 279-1001.

1y,

Sarett Environmental Inc.

Richard Lefrak, Charles Mehlman

115 West 30th Street • 11th Floor ' New York, New York 10001 • 212.279.1001 • 888.466.3620 , Fax: 212.279.6747

liotnc t'ftic:: The Bellevue • Suite n00 • 200 s. Broad strcet • Philadelphia. P.A I')102 ' 215 732 y4Q) • 888 7814 t378 ' Fax 215 7 32.0559

%% t .-,L( Fuvi ion men: ii it m

NYC-WTC 000095630

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000095630Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121364 · Box DEP Box 48

Chain of custody for air samples collected at 345 South End Avenue buildings in late January and early February 2002.

Similar indexed content

Compare copies and versions →