Hillmann Environmental Group, LLC
SECTION 4— DISCUSSION
While on site, Hillmann performed various types of air sampling and observed work conditions.
4.1 Temperature
The American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE) recommends temperatures be kept between 66°F and 76°F. In the occupied space, temperatures ranged from 69°F to 78°F, and were above the recommended range in many areas.
4.2 Relative Humidity
ASHRAE recommends relative humidity range between 39% to 69%. Relative humidity levels in the subject space ranged from 39% to 64% and were above the recommended range in some areas.
4.3 Carbon Dioixide
ASHRAE recommends carbon dioxide levels remain below an outdoor reading plus 700 ppm. The outdoor readings ranged from 521 ppm to 535 ppm, therefore the recommended limits were 1221 ppm to 1235 ppm. Carbon dioxide levels ranged from 521 ppm to 1044 ppm. Carbon dioxide levels did not exceed the recommended range.
4.4 Carbon Monoxide
Carbon monoxide, a colorless, odorless gas, is a by-product of incomplete combustion. Carbon monoxide combines with hemoglobin in the blood to cause carboxyhemoglobin poisoning. Carbon monoxide can be released by many different sources such as: motor vehicle exhaust (intakes for the ventilation system located near a loading dock), tobacco smoke, and cracked exchangers on gas-fired heating appliances. The standards for Carbon Monoxide are the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) of 35 ppm, the Occupational Safety and Health Administration (OSHA) Permissible Exposure Level (PEL) of 35 ppm, and the Environmental Protection Agency (EPA) National Ambient Air Quality Standard (NAAQS) of 9 ppm. Carbon monoxide levels measured in the occupied areas ranged from below the limit of detection of 1 ppm to 2 ppm, and were below the recommended limits.
4.5 Volatile Organic Compounds
Volatile organic compounds are carbon-containing compounds that boil at temperatures low enough that they can become gasses under normal conditions. They are frequently used as solvents and cleaners and can be given off by such materials as plastics and wiring insulation, especially if these materials are heated. Volatile organic compounds were measured by Photo Ionization Detector (P.I.D.). Hillmann recommends that levels detected by P.I.D. remain below three times the outdoor reading. Since the outdoor reading was below the limit of detection of 0.1 ppm, the recommended limit would be 0.3 ppm. In the subject space, levels were found to range from below the limit of detection of 0.1 ppm to 7.4 ppm. Levels measured by P.I.D. remained below this limit except for one reading in the Penthouse. However, this elevated reading can be attributed to adjacent roofing work that was occurring at the time of the investigation. A follow-up reading showed that levels had returned to normal.
Cushman & Wakefield/44 Wall Street, New York, NY/Project Number N3-7476 Page 8
NYC-WTC 000094940
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000093400
A license agreement document regarding exterior cleaning services for the property at 65 Liberty Street.
12 shared non-person entities · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
21 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120388
Laboratory report detailing air sampling and dust analysis conducted at 88 Pine Street from September 13 to 21, 2001.
25 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
12 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099818
Billing record for asphalt and gravel roof cleanup services performed at 55 Nassau Street in November 2002.
6 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125801
Cover sheet for a fax transmission from DEP regarding the 105 Duane Street site file.
16 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000111963
Billing statement from Fiber Control Inc. for work performed at the 12 Vesey Street job site.
5 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123194
Invoice for roof asbestos abatement work completed at 198 Broadway covering nearly 25,000 square feet.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115228
Invoice from Benjamin Kurzban & Son to the DEP for work completed at 213 Pearl Street on September 24, 2002.
5 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
11 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000100474
Billing statement from a contractor detailing charges for environmental cleanup and facade work.
6 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000150233
Cover page for a laboratory report regarding landfill operations, dated October 2001.
Cited alongside this record in an Ask answer
Review draft of an environmental health and safety plan for debris operations at Staten Island Landfill.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer