AKRF,Inc. 111-115 Broadway,New York,New York

humidity levels observed throughout the buildings were within the recommended levels. Temperature readings up to 79.4 degrees Fahrenheit were observed within the building. However, because temperature and the remaining environmental conditions are heavily dependent upon occupancy and the building systems' meeting of those occupancy loads, AKRF does not anticipate that this is an immediate area of concern. Carbon Dioxide (COQ, Carbon dioxide is a normal constituent in the air. Exhaled breath from building occupants is the primary source of carbon dioxide indoors. Carbon dioxide has been widely used in the industrial hygiene community as a surrogate for various occupant- generated indoor contaminants, such as cigarette smoke and bioeffluents, that are known to cause annoyance, irritation, or discomfort among building occupants. For buildings or zones of buildings where air cleaning to remove smoke and bioeffluents is not provided, the performance criteria established in ASHRAE standard 62-1999 (Ventilation for Acceptable Indoor Air Quality), recommends that carbon dioxide concentrations be maintained below 700 ppm above the outside air level (equivalent to about 15 cubic feet per minute [cfm] outdoor air per occupant). Carbon- dioxide levels throughout the buildings were observed to be less than 1,000 ppm (estimated from 700 ppm in addition to an outdoor level of 300 ppm). Carbon Monoxide (CO) Carbon monoxide is a by-product of combustion. ASHRAE Standard 62-1999 recommends that indoor airborne carbon monoxide concentrations do not exceed 9 ppm. The intent of the recommendation is to prevent annoyance and discomfort among a substantial number of occupants. AKRF compared indoor and outdoor carbon monoxide concentration levels for evaluation purposes. Indoor concentrations exceeding outdoor concentrations would suggest an indoor source of carbon monoxide, such as an improperly vented combustion appliance, which should be corrected. The OSHA PEL is 50 ppm, while the NIOSH REL is 35 ppm and the ACGIH TLV is 25 ppm. Carbon monoxide levels observed throughout the buildings were less than 2 ppm.

Page 5

NYC-WTC 000132585

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000132585Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132654 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Similar indexed content

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Similar indexed content

NYC-WTC_000132548 · Box DEP Box 54

Cover letter from Capital Properties submitting additional air quality monitoring results for Broadway buildings to DEP.

Similar indexed content

Compare copies and versions →