Table of lead concentration results from air samples taken at various floors of 86 Trinity Place on September 28, 2001.

NYC-WTC_000094519

Folder label: “86 TRINITY PLACE Block: 51 Lot: 13

Page image
Scanned page image, NYC-WTC_000094519
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

99i28i20P1 19:14 63158,03135 E /1RO'=C1EN' C'4SLrAN PAGE 0~

American Stock Exchange, 28 Septsnber 2001

86 Trinity Place Lead in Air Results Location Air Volume Liters Results E,rg/& Post 2 Sec A Main Trading 1,200 < 5.0 Floor Post 8 Sec G Main Trading 1,200 < 5.0 Floor 15* floor north side 1,200 39; 120' floor central 1,200 445 10'^ floor central 1,200 <5.0 76i floor central 1,200 < 5.0 Harry's Trading floor 1,200 < 5.0

22 Thames Street Lead in Air Results Location Air Volume Liters Results xcg/m3 Red room post 21 MF8 1,200 < 5.0 10' floor north side 2,450 <5.0

9' floor central 1,580 9.0

76' floor central 2,020 11.0

Except for the 150i floor and the 12* floor these values are all less than the OSHA lead PEL of 50 Before and during the time of air sampling the fire escape doors to these floors were left open all day and all night to cool the floor. It is believed that the lead in these samples blew in through the open fire escape doors and deposited on the filter media of the samples. We believe that the lead levels in these spaces were temporary and that they settled to the Hoar. The 15°i floor and 1? floor were re- sampled on September 29*, 2001, to more fully characterize the lead in air values.

The respirable dust (breathable) in air samples were collected from areas considered representative of the building. Respirable dust samples were collected to show particle dust mass and the distributicn of particle size. Only one sample was collected from each area to speed up the building screening process. The respirable dust in air results are presented i-1 the tables below.

86 Trinity Place Respirable Dust in Air Results Location Air Volume Results 1-5m 6-10km >10rrn Liters U*rn. Post 2 Sze r Main Trading 600 < 5.0 <1% <0'/c <0% Floor

Page 3 of 9

NYC-WTC 000094519

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000094519Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →