NYC-WTC_000093852
Brief explaining risks of sandblasting and chemical treatments on historic building materials.
Same agency, volume and box · similarity 0.881
machine-extracted · confidence unavailable · Check page ↗Technical document describing characteristics, problems, and maintenance of glazed architectural terra-cotta.
NYC-WTC_000093838–000093851Folder label: “LANDMARK INFORMATION”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Preservation Brief 7: The Preservation of Historic Glazed Architectural Terra-Cotta Page 9 of 14
mitigate these problems. This may include the installation of relieving joints, shelf angles or flexible joints. In any case, stress-related and structural deterioration, like water-related deterioration, must be stopped before effective consolidation or replacement efforts may begin.
Cleaning: The successful cleaning of glazed architectural terra-cotta removes excessive soil from the glazed surface without damaging the masonry unit itself. Of the many cleaning materials available, the most widely recommended are water, detergent, and a natural or nylon bristle brush. More stubborn pollution or fire-related dirt or bird droppings can be cleaned with steam or weak solutions of muriatic or oxalic acid.
A note of caution: Any acids, when used in strong enough solutions, may themselves deteriorate mortar and "liberate" salts within the masonry system, producing a situation called efflorescence.
Commercial cleaning solutions may be appropriate but probably are not necessary when water and detergent will suffice. There are, however, certain cleaning techniques for glazed terra-cotta which are definitely not recommended and which would damage the surface of the material. These include: all abrasive cleaning measures (especially sandblasting), the use of strong acids, (particularly fluoride-based acids), high-pressure water cleaning and the use of metal bristle brushes. All of these techniques will irreparably harm the glaze in one fashion or another and subsequently expose the porous tile body to the damaging effects of water.
It is important to remember that glazed architectural terra-cotta was designed to be cleaned cheaply and easily. This, in fact, was one of its major assets and was much advertised in the selling of the material early in this century.
Waterproofing: The covering of crazed glazing with waterproof coatings is the subject of an ongoing controversy today. The question involves whether or not the micro-cracks conduct substantial amounts of water into the porous tile body. Tests indicate that the glaze on new unexposed terra-cotta is itself not completely waterproof. Some testing also indicates that most crazing on historic glazed terra-cotta does not substantially increase the flow of moisture into the porous tile body when compared to new material. Excessive and serious crazing is, however, an exception and the coating of those areas on a limited scale may be wholly appropriate.
In an effort to stem water-related deterioration, architects and building owners often erroneously attribute water-related damage to glaze crazing when the source of the deterioration is, in fact, elsewhere: deteriorated caulking, flashing, etc. The waterproof coating of glazed architectural terra-cotta walls may cause problems on its own. Outward migration of water vapor normally occurs through the mortar joints in these systems. The inadvertent sealing of these joints in the wholesale coating of the wall may exacerbate an already serious situation. Spalling of the glaze, mortar, or porous body will, more than likely, result.
Repointing: Repointing of mortar which is severely deteriorated or improperly or infrequently maintained is one of the most useful preservation activities that can be performed on historic glazed architectural terra-cotta buildings. Ongoing and cyclical repointing guarantees the long life of this material. Repointing should always be carried out with a mortar which has a compressive strength (measured in p.s.i.) lower than the adjacent masonry unit. Hard (Portland cement) or coarsely screened mortars may cause point loading and/or prevent the outward migration of the water through the mortar joints, both of which ultimately damage the terra-cotta unit. Repointing with waterproof caulking
http://www2.cr.nps.gov/tps/briefs/brief07.htm 10/3/2001
NYC-WTC 000093846
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000093852
Brief explaining risks of sandblasting and chemical treatments on historic building materials.
Same agency, volume and box · similarity 0.881
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093728
Appendix B outlining performance standards and cleaning requirements for historic building exteriors.
Same agency, volume and box · similarity 0.854
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093788
Fax transmittal from the Mayor's Office regarding a March 2002 meeting with the building group.
Same agency, volume and box · similarity 0.829
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164903
Forwarded programmatic agreement documentation addressing post-disaster building cleaning procedures and eligible building list for recovery efforts.
Similar document embedding; no shared entity or topic indexed. · similarity 0.845
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
Similar document embedding; no shared entity or topic indexed. · similarity 0.827
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152327
A financial document from late September 2001 related to water supply operations and emergency response costs.
1 shared topics · similarity 0.825
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150931
Cover fax from the Mayor's Office forwarding DEP documents regarding exterior clean-up to be reviewed before a meeting with building owners.
Similar document embedding; no shared entity or topic indexed. · similarity 0.824
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000166488
Department of Buildings report containing findings and recommendations regarding the World Trade Center site.
Similar document embedding; no shared entity or topic indexed. · similarity 0.821
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153308
Draft advisory outlining required safety assessments and utility checks before allowing residents to return to buildings near the World Trade Center.
Similar document embedding; no shared entity or topic indexed. · similarity 0.818
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
1 shared non-person entities · similarity 0.817
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128425
Document excerpt describing compliance requirements for environmental remediation work at 94 Greenwich Street.
Similar document embedding; no shared entity or topic indexed. · similarity 0.816
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000111934
Document outlining regulatory compliance and follow-up visual assessments conducted by DEP at buildings near the World Trade Center.
Similar document embedding; no shared entity or topic indexed. · similarity 0.815
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000093580
Archival reference document with minimal visible content related to WTC-era landmark information.
Filed in the same folder
NYC-WTC_000093581
Administrative record from the Landmark Information folder regarding the World Trade Center site.
Filed in the same folder
NYC-WTC_000093582
Administrative record from the Landmark Information folder regarding the World Trade Center site.
Filed in the same folder
NYC-WTC_000093583
Landmarks Preservation Commission notice withdrawing an application for alterations at 192 Broadway due to lack of landmark status.
Filed in the same folder
Permit for minor work issued by the Landmarks Preservation Commission for alterations at 55 Liberty Street.
Filed in the same folder