NYC Law Department release Independent mirror · updated as the City releases more · v1.5.1 ☕ Buy me a coffee
← Document results/DEP Box 66/NEWE 1/11/2002 AD 31456 - AE00110 Batches 16390 16391 16402 copies made
Document / 60 pages
Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AD31550
Sample Date/Time: Friday, January 11, 2002 13:36:25
Sample Type: Spike - 2
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AD31550.2043
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 25628.011 2.539 0.042 53.29290 2.38 ug/L
|> Sc-1 45 608065.632 3.564 608065.632 ug/L
L Mn 55 1368824.148 2.323 2.252 78.07170 4.23 ug/L
r> In 115 1265669.867 1.538 1265669.867 ug/L
I Sb 121 426656.085 0.552 0.337 52.31847 1.89 ug/L
L Sb 123 327508.002 0.757 0.259 52.32872 0.99 ug/L
r> Ho 165 1728238.334 1.450 1728238.334 ug/L
L Tl 205 1312741.780 1.958 0.759 49.09252 1.11 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9 106.592
|> Sc-1 45 95.767
L Mn 55 94.286
r> In 115 95.973
I Sb 121 104.464
L Sb 123 104.485
r> Ho 165 96.225
L Tl 205 98.170
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be 9Linear Thru Zero 0.999992
|> Sc-1 45Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 115Linear Thru Zero
I Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165Linear Thru Zero
L Tl 205Unear Thru Zero 0.999977