Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AD31551
Sample Date/Time: Friday, January 11, 2002 13:38:38
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AD31551.2044
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 13.000 27.735 0.000 0.00456 174.46 ug/L
|> Sc-1 45 607599.681 4.234 607599.681 ug/L
L Mn 55 1595267.020 1.940 2.626 91.04597 2.30 ug/L
r> In 115 1252902.750 0.472 1252902.750 ug/L
I Sb 121 1084.076 5.353 0.001 0.13012 5.54 ug/L
L Sb 123 820.731 2.352 0.001 0.12842 2.91 ug/L
r> Ho 165 1735985.857 1.636 1735985.857 ug/L
L Tl 205 434.348 10.766 0.000 0.00837 19.56 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery I nt Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
|> Sc-1 45 95.694
L Mn 55
r> In 115 95.005
I Sb 121
L Sb 123
r> Ho 165 96.657
L Tl 205
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be OLinear Thru Zero 0.999992
|> Sc-1 45Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 11 SLinear Thru Zero
I Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165Linear Thru Zero
L Tl 205Linear Thru Zero 0.999977