Method 200.8 - Summary Report
Sample ID: AD30424
Sample Date/Time: Wednesday, December 26, 2001 13:54:57
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\Elandata\Method\NEWE200.8.mth
Dataset File: d:\Elandata\Dataset\daily performance\AD30424.1433
Sample Prep Volume (ml):
Initial Sample Quantity (mg):
Aliquot Volume (ml):
Diluted To Volume (ml):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 17.000 41.177 0.000 0.00595 228.21 ug/L
i> Sc-1 45 663240.705 1.054 663240.705 ug/L
I V 51 4099.298 1.069 0.004 0.20753 2.75 mg/L
L Mn 55 396126.888 0.734 0.597 20.76366 1.80 ug/L
r> In 115 1495746.688 0.450 1495746.688 ug/L
I Sb 121 558.689 1.802 0.000 0.04964 2.35 ug/L
L Sb 123 446.938 2.930 0.000 0.05234 3.39 ug/L
r> Ho 165 1949218.651 4.120 1949218.651 ug/L
L Tl 205 160.670 7.187 -0.000 -0.02543 1.20 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
i> Sc-1 45 90.565
I V 51
L Mn 55
r> In 115 89.828
I Sb 121
L Sb 123
r> Ho 165 102.709
L Tl 205
NYC-WTC_000085132
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000085132Source: NYC Law Department, mirrored locally
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.