NYC Law Department release Independent mirror · updated as the City releases more · v1.5.1 ☕ Buy me a coffee
← Document results/DEP Box 66/NEWE 1/11/2002 AD 31456 - AE00110 Batches 16390 16391 16402 copies made
Document / 60 pages
Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AD31466
Sample Date/Time: Friday, January 11, 2002 13:20:22
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AD31466.2036
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 11.667 21.571 0.000 0.00150 362.87 ug/L
|> Sc-1 45 613787.940 4.085 613787.940 ug/L
L Mn 55 584822.558 2.382 0.953 33.03505 4.84 ug/L
r> In 115 1274639.732 0.714 1274639.732 ug/L
I Sb 121 437.015 5.839 0.000 0.04906 7.04 ug/L
L Sb 123 350.102 3.122 0.000 0.05147 2.73 ug/L
r> Ho 165 1744774.553 2.276 1744774.553 ug/L
L Tl 205 266.673 6.670 0.000 0.00208 27.22 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
1> Sc-1 45 96.668
L Mn 55
r> In 115 96.653
I Sb 121
L Sb 123
r> Ho 165 97.146
L Tl 205
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be 9Linear Thru Zero 0.999992
|> Sc-1 45Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 115Linear Thru Zero
I Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165Linear Thru Zero
L Tl 205Linear Thru Zero 0.999977