Method 200.8 - Summary Report
Sample ID: AD30115
Sample Date/Time: Wednesday, December 26, 2001 12:50:15
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\Elandata\Method\NEWE200.8.mth
Dataset File: d:\Elandata\Dataset\daily performance\AD30115.1420
Sample Prep Volume (ml):
Initial Sample Quantity (mg):
Aliquot Volume (ml):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 11.667 21.571 -0.000 -0.00581 81.89 ug/L
1> Sc-1 45 718546.194 2.022 718546.194 ug/L
I V 51 11602.183 1.605 0.014 0.67808 2.00 mg/L
L Mn 55 920049.756 0.724 1.280 44.54379 1.92 ug/L
r> In 115 1551258.943 0.290 1551258.943 ug/L
I Sb 121 993.398 1.109 0.001 0.09101 1.11 ug/L
L Sb 123 761.174 3.412 0.000 0.09084 3.47 ug/L
r> Ho 165 1912962.823 0.259 1912962.823 ug/L
L Tl 205 219.005 5.971 -0.000 -0.02354 1.74 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
|> Sc-1 45 98.117
I V 51
L Mn 55
r> In 115 93.161
I Sb 121
L Sb 123
r> Ho 165 100.799
L Tl 205
NYC-WTC_000085119
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000085119Source: NYC Law Department, mirrored locally
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.