Method 200.8 - Summary Report
Sample ID: AD30117
Sample Date/Time: Wednesday, December 26, 2001 12:52:11
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\Elandata\Method\NEWE200.8.mth
Dataset File: d:\Elandata\Dataset\daily performance\AD30117.1421
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 17.334 12.010 0.000 0.00457 74.62 ug/L
i> Sc-1 45 704300.012 1.606 704300.012 ug/L
I V 51 5245.566 2.760 0.006 0.26735 3.65 mg/L
L Mn 55 479864.780 3.501 0.681 23.68663 3.15 ug/L
r> In 115 1561222.930 1.520 1561222.930 ug/L
I Sb 121 593.692 1.528 0.000 0.05071 3.48 ug/L
L Sb 123 430.604 3.047 0.000 0.04772 2.25 ug/L
r> Ho 165 1910431.562 0.905 1910431.562 ug/L
L Tl 205 174.003 2.299 -0.000 -0.02492 0.31 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
|> Sc-1 45 96.171
I V 51
L Mn 55
r> In 115 93.760
I Sb 121
L Sb 123
r> Ho 165 100.665
L Tl 205
NYC-WTC_000085120
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000085120Source: NYC Law Department, mirrored locally
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.