NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/DEP Box 66/NEWE 1/11/2002 AD 31456 - AE00110 Batches 16390 16391 16402 copies made
Document / 60 pages

Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002

Machine-extracted title · confidence 85%

ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.

NYC-WTC_000085478–000085537

Folder label: “NEWE 1/11/2002 AD 31456 - AE00110 Batches 16390 16391 16402 copies made”

Page image
Scanned page image, NYC-WTC_000085495
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Method 200.8 - Summary Report Sample ID: AD31458 Sample Date/Time: Friday, January 11, 2002 13:05:55 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWE200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AD31458.2030 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):

Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 12.667 44.891 0.000 0.00325 373.20 ug/L i> sc-1 45 623371.579 3.352 623371.579 ug/L L Mn 55 571800.160 2.926 0.917 31.77653 2.81 ug/L r> In 115 1321710.386 1.613 1321710.386 ug/L I Sb 121 638.029 4.934 0.000 0.07075 4.83 ug/L L Sb 123 483.946 1.500 0.000 0.07000 3.05 ug/L r> Ho 165 1777002.096 2.935 1777002.096 ug/L L Tl 205 358.344 8.756 0.000 0.00525 25.51 ug/L

QC Calculated Values Analyte Mass QC Std % Recovery I nt Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 |> Sc-1 45 98.177 L Mn 55 r> In 115 100.223 I Sb 121 L Sb 123 r> Ho 165 98.940 L Tl 205

Calibration Analyte MassCurve Type Correlation Coefficient r Be 9Linear Thru Zero 0.999992 |> Sc-1 45Linear Thru Zero L Mn 55Linear Thru Zero 0.999983 r> In 11 SLinear Thru Zero I Sb 121 Linear Thru Zero 0.999998 L Sb 123Linear Thru Zero 1.000000 r> Ho 165Linear Thru Zero L Tl 205Linear Thru Zero 0.999977

Sample ID: AD31458 Report Date/Time: Friday, January 11, 2002 13:06:27 Page 1

NYC-WTC_000085495

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000085495Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

ICP-MS summary report, Jan 14 2002 · Box DEP Box 66

NYC-WTC_000085539

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Manganese, Indium, and Antimony.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 18 2002 · Box DEP Box 66

NYC-WTC_000085865

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Manganese, Indium, and Antimony.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 4 2002 · Box DEP Box 66

NYC-WTC_000085362

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.974

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 3 2002 · Box DEP Box 66

NYC-WTC_000085227

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.973

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →