Quantitation Report (Not Reviewed)
Data File : C:\HPCHEM\l\DATA\02aprl9\0419C10.D Vial: 2
Acq On : 19 Apr 2002 11:00 am Operator: 201-wb
Sample : cal 10 Inst : GC/MS Ins
Mise : April 19, 2002 Multiplr: 1.00
MS Integration Params: RTEINT.P
Quant Time: Apr 19 11:38 2002 Quant Results File: HP031802.RES
Quant Method : C:\HPCHEM\1\METHODS\HP031802.M (RTE Integrator)
Title : VOCs BY EPA METHOD 524
Last Update : Mon Apr 15 10:00:49 2002
Response via : Initial Calibration
DataAcq Meth : HP031802
Compound R.T. Qlon Response Cone Unit Qvalue
48) P & M-XYLENE 22.07 106 1206253 19.63 ug/L 84
49) O-XYLENE 23.04 91 1450503 10.24 ug/L 95
50) STYRENE 23.09 104 913658 9.73 ug/L 95
51) 1,1,2,2-TETRACHLOROETHANE 24.13 83 224111 8.65 ug/L 97
53) BROMOFORM 23.96 173 147739 10.15 ug/L 98
54) ISOPROPYLBENZENE 23.75 105 1593289 10.96 ug/L 98
55) 1,2,3-TRICHLOROPROPANE 24.45 110 76216 10.83 ug/L 84
56) N-PROPYLBENZENE 24.64 91 2046787 10.83 ug/L 97
57) BROMOBENZENE 24.88 156 387993 10.15 ug/L 92
. 58) 1,3,5-TRIMETHYLBENZENE 24.94 105 1425807 11.05 ug/L 97
59) 2-CHLOROTOLUENE 25.11 91 1417096 10.90 ug/L 93
60) 4-CHLOROTOLUENE 25.18 91 1292965 11.55 ug/L 94
61) TERT-BUTYLBENZENE 25.74 119 1249018 10.61 ug/L 92
62) 1,2,4-TRIMETHYLBENZENE 25.83 105 1480345 10.97 ug/L 96
63) SEC-BUTYLBENZENE 26.20 105 1691500 10.46 ug/L 97
64) P-ISOPROPYLTOLUENE 26.46 119 1322711 10.48 ug/L 95
65) 1,3-DICHLOROBENZENE 26.82 146 722430 9.90 ug/L 98
66) 1,4-DICHLOROBENZENE 27.04 146 719400 9.54 ug/L 99
67) N-BUTYLBENZENE 27.34 91 1415859 11.04 ug/L 98
68) 1,2-DICHLOROBENZENE 27.89 146 604238 9.68 ug/L 97
69) 1,2-DIBROMO-3-CHLOROPROPAN 29.68 157 28500 7.41 ug/L 99
70) 1,2,4-TRICHLOROBENZENE 31.97 180 391646 9.93 ug/L 99
71) HEXACHLOROBUTADIENE 32.28 225 255040 11.93 ug/L 96
72) NAPHTHALENE 32.83 128 357079 7.38 ug/L 98
73) 1,2,3-TRICHLOROBENZENE 33.52 180 298311 9.68 ug/L 97
74) NITROBENZENE 29.90 77 140952 160.53 ug/L 87