Data File C:\HPCHEM\l\DATA\02APR03\0403C10B.D Vial: 3
Acq On 3 Apr 2002 4:08 pm Operator: 201-wb
Sample cal 10 Inst : GC/MS Ins
Mise Multiplr: 1.00
MS Integration Params: RTEINT.P
Quant Time: Apr 3 16:46 2002 Quant Results File: HP031802.RES
Quant Method : C:\HPCHEM\1\METHODS\HP031802.M (RTE Integrator)
Title : VOCs BY EPA METHOD 524
Last Update : Wed Apr 03 15:28:09 2002
Response via : Initial Calibration
DataAcq Meth : HP031802
Compound R.T. Qlon Response Cone Unit Qvalue
48) P & M-XYLENE 22.05 106 2333817 22.90 ug/L 89
49) 0-XYLENE 23.04 91 2769795 11.79 ug/L 96
50) STYRENE 23.09 104 1752986 11.25 ug/L 97
51) 1,1,2,2-TETRACHLOROETHANE 24.11 83 368337 8.57 ug/L 96
53) BROMOFORM 23.95 173 293793 11.83 ug/L 98
54) ISOPROPYLBENZENE 23.75 105 3221949 12.99 ug/L 99
55) 1,2,3-TRICHLOROPROPANE 24.45 110 136441 10.26 ug/L 97
56) N-PROPYLBENZENE 24.62 91 3994139 12.38 ug/L 95
57) BROMOBENZENE 24.87 156 772910 11.85 ug/L 97
58) 1,3,5-TRIMETHYLBENZENE 24.94 105 2813744 12.78 ug/L 98
59) 2-CHLOROTOLUENE 25.11 91 2704656 12.20 ug/L 96
60) 4-CHLOROTOLUENE 25.18 91 2350488 12.31 ug/L 98
61) TERT-BUTYLBENZENE 25.74 119 2548339 12.69 ug/L 96
62) 1,2,4-TRIMETHYLBENZENE 25.83 105 2905746 12.62 ug/L 95
63) SEC-BUTYLBENZENE 26.20 105 3461748 12.55 ug/L 97
64) P-ISOPROPYLTOLUENE 26.46 119 2733511 12.69 ug/L 96
65) 1,3-DICHLOROBENZENE 26.82 146 1463510 11.76 ug/L 99
66) 1,4-DICHLOROBENZENE 27.04 146 1450430 11.27 ug/L 98
67) N-BUTYLBENZENE 27.34 91 2803709 12.81 ug/L 98
68) 1,2-DICHLOROBENZENE. 27.89 146 1172596 11.01 ug/L 96
69) 1,2-DIBROMO-3-CHLOROPROPAN 29.68 157 56934 8.66 ug/L 94
70) 1,2,4-TRICHLOROBENZENE 31.-97 180 803809 11.95 ug/L 96
71) HEXACHLOROBUTADIENE 32.28 225 557529 16.04 ug/L 94
72) NAPHTHALENE 32.81 128 768672 9.31 ug/L 99
73) 1,2,3-TRICHLOROBENZENE 33.52 180 621505 11.82 ug/L 96
74) NITROBENZENE 29.90 77 287690 170.63 ug/L 94
(#) = qualifier out of range (m) = manual integration